ZHCSLF8A June   2020  – June 2021 INA228-Q1

PRODUCTION DATA  

  1. 特性
  2. 应用
  3. 说明
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Timing Requirements (I2C)
    7. 6.7 Timing Diagram
    8. 6.8 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Versatile High Voltage Measurement Capability
      2. 7.3.2 Internal Measurement and Calculation Engine
      3. 7.3.3 Low Bias Current
      4. 7.3.4 High-Precision Delta-Sigma ADC
        1. 7.3.4.1 Low Latency Digital Filter
        2. 7.3.4.2 Flexible Conversion Times and Averaging
      5. 7.3.5 Shunt Resistor Drift Compensation
      6. 7.3.6 Integrated Precision Oscillator
      7. 7.3.7 Multi-Alert Monitoring and Fault Detection
    4. 7.4 Device Functional Modes
      1. 7.4.1 Shutdown Mode
      2. 7.4.2 Power-On Reset
    5. 7.5 Programming
      1. 7.5.1 I2C Serial Interface
        1. 7.5.1.1 Writing to and Reading Through the I2C Serial Interface
        2. 7.5.1.2 High-Speed I2C Mode
        3. 7.5.1.3 SMBus Alert Response
    6. 7.6 Register Maps
      1. 7.6.1 INA228-Q1 Registers
  8. Application and Implementation
    1. 8.1 Application Information
      1. 8.1.1 Device Measurement Range and Resolution
      2. 8.1.2 Current , Power, Energy, and Charge Calculations
      3. 8.1.3 ADC Output Data Rate and Noise Performance
      4. 8.1.4 Input Filtering Considerations
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Select the Shunt Resistor
        2. 8.2.2.2 Configure the Device
        3. 8.2.2.3 Program the Shunt Calibration Register
        4. 8.2.2.4 Set Desired Fault Thresholds
        5. 8.2.2.5 Calculate Returned Values
      3. 8.2.3 Application Curves
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Example
  11. 11Device and Documentation Support
    1. 11.1 接收文档更新通知
    2. 11.2 支持资源
    3. 11.3 Trademarks
    4. 11.4 Electrostatic Discharge Caution
    5. 11.5 术语表
  12. 12Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Timing Requirements (I2C)

MIN NOM MAX UNIT
I2C BUS (FAST MODE)
F(SCL) I2C clock frequency 1 400 kHz
t(BUF) Bus free time between STOP and START conditions 600 ns
t(HDSTA) Hold time after a repeated START condition. After this period, the first clock is generated. 100 ns
t(SUSTA) Repeated START condition setup time 100 ns
t(SUSTO) STOP condition setup time 100 ns
t(HDDAT) Data hold time 10 900 ns
t(SUDAT) Data setup time 100 ns
t(LOW) SCL clock low period 1300 ns
t(HIGH) SCL clock high period 600 ns
tF Data fall time 300 ns
tF Clock fall time 300 ns
tR Clock rise time 300 ns
I2C BUS (HIGH-SPEED MODE)
F(SCL) I2C clock frequency 10 2940 kHz
t(BUF) Bus free time between STOP and START conditions 160 ns
t(HDSTA) Hold time after a repeated START condition. After this period, the first clock is generated. 100 ns
t(SUSTA) Repeated START condition setup time 100 ns
t(SUSTO) STOP condition setup time 100 ns
t(HDDAT) Data hold time 10 125 ns
t(SUDAT) Data setup time 20 ns
t(LOW) SCL clock low period 200 ns
t(HIGH) SCL clock high period 60 ns
tF Data fall time 80 ns
tF Clock fall time 40 ns
tR Clock rise time 40 ns