Place the power-supply bypass capacitor as close as possible to the supply and ground pins. The recommended value of this bypass capacitor is 0.1 µF. Add more decoupling capacitance to compensate for noisy or high-impedance power supplies.
Connect RLIMIT to the ground pin as
directly as possible to limit additional capacitance on this node. If possible,
route this connection to the same plane in order to avoid vias to internal
planes. If the connection cannot be routed on the same plane and must pass
through vias, make sure that a path is routed from RLIMIT back to the
ground pin, and that RLIMIT is not simply connected directly to a
ground plane.
Pull up the open-drain output pin to the supply voltage rail through a 10-kΩ pullup resistor.