4 Revision History
Changes from Revision A (March 2021) to Revision B (Febuary 2023)
- 将整个文档中的标准名称从“DIN V VDE V 0884-11:2017-01”更改为“DIN EN IEC 60747-17 (VDE 0884-17)”Go
- 通篇将 CMTI 从“50kV/us(最小值)和 75kV/us(典型值)”更新为“100kV/us(最小值)和 150kV/us(典型值)”Go
- 通篇删除了对标准 IEC/EN/CSA 60950-1 的引用Go
- 通篇删除了标准版本和年份参考以及所有标准名称中的“待认证”参考Go
- 根据 DIN EN IEC 60747-17 (VDE 0884-17),通篇将测试条件和最大浪涌隔离电压 (VIOSM) 的值从“6250VPK”更改为“10000VPK”Go
- Updated VIORM From: "1500 VPK" To: "2121 VPK" to match VDE certificate Go
- Updated VIOWM From: "1060 VRMS" To: "1500
VRMS" and From: "1500 VDC" To: "2121 VDC" throughout
the documentGo
- Added Maximum impulse voltage (VIMP) specification in Insulation Specifications per DIN EN IEC 60747-17 (VDE 0884-17) Go
- Clarified method b test conditions of Apparent charge (qPD) in Insulation Specification Go
- Changed working voltage lifetime margin From: "87.5%" To: "50%", minimum
required insulation lifetime From: "37.5 years" To: "30 years" and insulation lifetime per
TDDB From: "220 years" To: "36 years" in Section 9.2.3.1
per DIN EN IEC 60747-17 (VDE 0884-17) Go
- Changed Figure 9-8 per DIN EN IEC 60747-17 (VDE 0884-17)Go
Changes from Revision * (January 2021) to Revision A (March 2021)