10 Revision History
Changes from Revision Q (August 2018) to Revision R (October 2024)
- 通篇将引用内容从电容隔离更新为隔离栅Go
- 更新了整个文档中的表格、图和交叉参考的编号格式Go
- Updated Thermal Characteristics, Safety Limiting Values, and Thermal Derating Curves to provide more accurate system-level thermal calculationsGo
- Updated electrical and switching characteristics to match device performanceGo
Changes from Revision P (August 2018) to Revision Q (January 2021)
- Removed nominal specifications in the RECOMMENDED OPERATING CONDITIONS tableGo
Changes from Revision O (April 2017) to Revision P (August 2018)
- 通篇将 (VDE V 0884-10):2006-12 更改为 DIN VDE V 0884-11:2017-01
Go
- 通篇将获得了 CSA 元件验收通知 5A 和 IEC 60950-1 批准 更改为获得了 CSA IEC 60950-1 和 IEC 62368-1 批准
Go
- Added the basic insulation working voltage for CSA in the Safety-Related Certifications tableGo
- Changed the VDE certification number from 40016131 to 40047657 in the Safety-Related Certifications tableGo
- Changed the maximum propagation delay and pulse-width distortion in each Switching Characteristics tableGo
- Changed ISO722x to ISO7220 for all part numbers for the Channel-to-channel output skew parameter in each Switching Characteristic tableGo
- Added ± 10% for the VCC1 and VCC2 voltages in the condition statement of the Switching Characteristics—5-V VCC1 and VCC2 Supplies tableGo
Changes from Revision N (September 2015) to Revision O (April 2017)
- Changed the Dissipation Characteristics table to Power Ratings. Combined the DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 Insulation Characteristics table IEC Package Characteristics, and IEC 60664-1 Ratings Table in the Insulation Specifications table. Changed the Regulatory Information table to Safety-Related Certifications
Go
- Deleted the maximum surge voltage, 4000 VPK for VDE in the Safety-Related Certifications tableGo
- Changed the CSA information in the Safety-Related Certifications tableGo
Changes from Revision M (October 2014) to Revision N (September 2015)
- 通篇将“VDE 认证”从“DIN EN 60747-5-5 (VDE 0884-5)”更改为“DIN V VDE V 0884-10 (VDE V 0884-10):2006-12”Go
- 将简化原理图 更新为质量更高的版本Go
- Changed the max value of the IN and OUT voltage from 6 to VCC + 0.5 in the Absolute Maximum Ratings table.Go
- Added the JEDEC package dimensions note in the IEC Package Characteristics tableGo
- Changed the DTI test condition From: IEC 60112 / VDE 0303 Part 1 To: DIN EN 60112 (VDE 0303-11); IEC 60112Go
- Added = 150°C to insulation resistance test condition in the DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 Insulation Characteristics table.Go
- Changed L(I01) MIN value from 4.8 to 4 in the IEC Package Characteristics table.Go
- Added the DTI parameter to the IEC Package Characteristics table.Go
- Added table row with input side VCC = X to the ISO7220x or ISO7221x Function table.Go
Changes from Revision L (January 2012) to Revision M (August 2014)
- 将该数据表的标题更改为 ISO722x 双通道数字隔离器
Go
- 添加了引脚配置和功能 部分、处理额定值 部分、功耗额定值 表、特性说明 部分、器件功能模式、应用和实施 部分、电源相关建议 部分、布局 部分、器件和文档支持 部分以及机械、封装和可订购信息 部分,更改了热性能信息 表Go
- 更新了“特性”部分Go
- 在“说明”的第二句中添加了“符合 VDE 标准、高达 4000VPK”Go
- Updated the Regulatory Information TableGo
- Added the min and max values to the Storage temperature parameter in the Absolute Maximum Ratings table.Go
- Changed in ROC table Max col, VIH row from VCC to 5.5Go
- Changed the L(I01) parameter name to external clearance (CLR) and L(I02) to external creepage (CPG). Also changed the input-to-output test voltage (VPR) parameter name to apparent charge (qpd)Go
- Changed the Device Options table, Input Threshold column from ≠ symbol to ~ symbol 6 places Go
- Changed the name of the Application Curve section to
Insulation Lifetime and moved to the Application Curves
sectionGo
- Changed Isolation Glossary
Go
Changes from Revision K (January 2010) to Revision L (January 2012)
- 将“特性”中的“由 3.3V 或 5V 电源供电”更改为“由 2.8V(C 级)、3.3V 或 5V 电源供电”Go
- 将“特性”中的“4000V(peak) 隔离,560Vpeak VIORM”更改为“4000VPK VIOTM,560VPK VIORM,符合 IEC 60747-5-2(VDE 0884,修订版 2)标准”Go
- Changed Note: (1) in the RECOMMENDED OPERATING CONDITIONS tableGo
- Added device options to VCC in the RECOMMENDED OPERATING CONDITIONS tableGo
- Changed the CTI MIN value From: ≥175 V To: ≥400 VGo
- Updated the Regulatory Information tableGo
- Changed Table Note: (1)Go
- Changed ICC1 and ICC2 test conditions in the 5-V tableGo
- Changed Table Note: (1)Go
- Changed ICC1 and ICC2 test conditions in the VCC1 at 5 V, VCC2 at 3.3 V tableGo
- Changed ICC1 and ICC2 test conditions in the VCC1 at 3.3 V, VCC2 at 5 V tableGo
- Changed Table Note (1)Go
- Changed ICC1 and ICC2 test conditions in the VCC1 and VCC2 at 3.3 V tableGo
- Changed Table Note (1)Go
- Added ELECTRICAL and Switching CHARACTERISTICS table for VCC1 and VCC2 at 2.8 V (ISO722xC-Only)Go
- Changed VCC Undervoltage Threshold vs Free-Air Temperature
Go
- Changed Failsafe Delay Time Test Circuit and Voltage Waveforms
Go
Changes from Revision J (May 2009) to Revision K ()
- Changed Note (2) From: Typical signaling rate under ideal conditions at 25°C. To: Typical signaling rate and Input pulse width are measured at ideal conditions at 25°C.Go
- Changed the RECOMMENDED OPERATING CONDITIONS so that Note (2) is associated with all device options in the Input pulse width and Signaling rateGo
- Changed column 2 of the AVAILABLE OPTIONS table From: Signaling Rate To: Max Signaling RateGo
Changes from Revision I (December 2008) to Revision J ()
- Changed ISO7221C Marked As column From: TI7221C To: I7221C in the AVAILABLE OPTIONS tableGo
Changes from Revision H (May 2008) to Revision I ()
- 向 UL 1577 特性要点中添加了“获得了 IEC 61010-1、IEC 60950-1 和 CSA 批准”Go
Changes from Revision G (March 2008) to Revision H ()
- Added Note: (1) to the RECOMMENDED OPERATING CONDITIONS tableGo
- Added Note: (1) to the ELECTRICAL CHARACTERISTICS: VCC1 and VCC2 at 5-V tableGo
- Added Note: (1) to the ELECTRICAL CHARACTERISTICS: VCC1 at 5 V, VCC2 at 3.3 V tableGo
- Added Note (1): to the ELECTRICAL CHARACTERISTICS: VCC1 at 3.3 V, VCC2 at 5 V tableGo
- Added Note (1): to the ELECTRICAL CHARACTERISTICS: VCC1 and VCC2 at 3.3 VGo
Changes from Revision F (August 2007) to Revision G ()
- 向数据表添加了器件型号 ISO7220B 和 ISO7221BGo
- 向“特性”列表中添加了 5Mbps 信令速率Go
- Added Part Numbers ISO7220B and ISO7221B to the ELECTRICAL CHARACTERISTICS: VCC1 and VCC2 at 5-V tableGo
- Added Part Numbers ISO7220B and ISO7221B to the ELECTRICAL CHARACTERISTICS: VCC1 at 5 V, VCC2 at 3.3 V tableGo
- Added Part Numbers ISO7220B and ISO7221B to the ELECTRICAL CHARACTERISTICS: VCC1 at 3.3 V, VCC2 at 5 V tableGo
- Added Part Numbers ISO7220B and ISO7221B to the ELECTRICAL CHARACTERISTICS: VCC1 and VCC2 at 3.3 VGo
- Added PROPAGATION DELAY vs FREE-AIR TEMPERATURE, ISO722xB, Propagation Delay vs Free-Air Temperature, ISO722xB
Go
- Added Part Numbers ISO7220B and ISO7221B to the AVAILABLE OPTIONS tableGo
Changes from Revision E (July 2007) to Revision F ()
- Added tsk(o) footnote to the SWITCHING CHARACTERISTICS: VCC1 and VCC2 at 5-V OPERATION tableGo
- Added tsk(pp) footnote to the SWITCHING CHARACTERISTICS: VCC1 and VCC2 at 5-V OPERATION tableGo
- Added tsk(pp) footnote to the SWITCHING CHARACTERISTICS: VCC1 at 5 V, VCC2 at 3.3 V OPERATION tableGo
- Added tsk(o) footnote to the SWITCHING CHARACTERISTICS: VCC1 at 5 V, VCC2 at 3.3 V OPERATION tableGo
- Added tsk(pp) footnote to the SWITCHING CHARACTERISTICS: VCC1 at 3.3 V, VCC2 at 5 V OPERATION tableGo
- Added tsk(o) footnote to the SWITCHING CHARACTERISTICS: VCC1 at 3.3 V, VCC2 at 5 V OPERATION tableGo
- Added tsk(pp) footnote to the SWITCHING CHARACTERISTICS tableGo
- Changed 3.3-VRMS Supply Current vs Signaling Rate - Re-scaled the Y-axisGo
- Changed 5-VRMS Supply Current vs Signaling Rate - New CurvesGo
Changes from Revision D (June 2007) to Revision E ()
- Changed 3.3-VRMS Supply Current vs Signaling Rate - New CurvesGo
- Changed 5-VRMS Supply Current vs Signaling Rate - Re-scaled the Y-axis Go
Changes from Revision C (May 2007) to Revision D ()
- Changed Typical ISO7220x Circuit Hook-Up - Pin 2 (INA) label From: OUTPUT to INPUTGo
Changes from Revision B (May 2007) to Revision C ()
- Added the Signaling rate values to the RECOMMENDED OPERATING CONDITIONS tableGo
- Changed the IEC 60664-1 RATINGS TABLE - Specification I-III test conditions From: Rated mains voltage ≤150 VRMS To: Rated mains voltage ≤300 VRMS. Added a row for the I-II specificationsGo
- Added ISO722xM Jitter vs Signaling Rate cross reference to the Peak-to-peak eye-pattern jitter of the SWITCHING CHARACTERISTICS tableGo
- Added Time-Dependent Dielectric Breakdown Test Results
Go
Changes from Revision A (August 2006) to Revision B ()
- Added the TYPICAL CHARACTERISTIC CURVES to the data sheet.Go
- Added the PARAMETER MEASUREMENT INFORMATION to the data sheetGo
- Added the APPLICATION INFORMATION section to the data sheetGo
- Added the ISOLATION GLOSSARY section to the data sheet Go
Changes from Revision * (July 2006) to Revision A ()
- 从 UL 1577 特性要点中删除了“并获得了 CSA 批准”Go
- Added option A to the AVAILABLE OPTIONS tableGo