SLLS868T September   2007  – April 2017 ISO7240C , ISO7240CF , ISO7240M , ISO7241C , ISO7241M , ISO7242C , ISO7242M

PRODUCTION DATA.  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Description (Continued)
  6. Pin Configurations and Functions
  7. Specifications
    1. 7.1  Absolute Maximum Ratings
    2. 7.2  ESD Ratings
    3. 7.3  Recommended Operating Conditions
    4. 7.4  Thermal Information
    5. 7.5  Power Ratings
    6. 7.6  Insulation Specifications
    7. 7.7  Safety-Related Certifications
    8. 7.8  Safety Limiting Values
    9. 7.9  Electrical Characteristics: VCC1 and VCC2 at 5-V Operation
    10. 7.10 Supply Current Characteristics: VCC1 and VCC2 at 5-V Operation
    11. 7.11 Electrical Characteristics: VCC1 at 5-V, VCC2 at 3.3-V Operation
    12. 7.12 Supply Current Characteristics: VCC1 at 5-V, VCC2 at 3.3-V Operation
    13. 7.13 Electrical Characteristics: VCC1 at 3.3-V, VCC2 at 5-V Operation
    14. 7.14 Supply Current Characteristics: VCC1 at 3.3-V, VCC2 at 5-V Operation
    15. 7.15 Electrical Characteristics: VCC1 and VCC2 at 3.3 V Operation
    16. 7.16 Supply Current Characteristics: VCC1 and VCC2 at 3.3 V Operation
    17. 7.17 Switching Characteristics: VCC1 and VCC2 at 5-V Operation
    18. 7.18 Switching Characteristics: VCC1 at 5-V, VCC2 at 3.3-V Operation
    19. 7.19 Switching Characteristics: VCC1 at 3.3-V and VCC2 at 5-V Operation
    20. 7.20 Switching Characteristics: VCC1 and VCC2 at 3.3-V Operation
    21. 7.21 Insulation Characteristics Curves
    22. 7.22 Typical Characteristics
  8. Parameter Measurement Information
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
    4. 9.4 Device Functional Modes
      1. 9.4.1 Device I/O Schematics
  10. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Isolated Data Acquisition System for Process Control
        1. 10.2.1.1 Design Requirements
        2. 10.2.1.2 Detailed Design Procedure
        3. 10.2.1.3 Application Curves
      2. 10.2.2 Isolated SPI for an Analog Input Module with 16 Inputs
        1. 10.2.2.1 Design Requirements
        2. 10.2.2.2 Detailed Design Procedure
        3. 10.2.2.3 Application Curve
      3. 10.2.3 Isolated RS-232 Interface
        1. 10.2.3.1 Design Requirements
        2. 10.2.3.2 Detailed Design Procedure
        3. 10.2.3.3 Application Curve
  11. 11Power Supply Recommendations
  12. 12Layout
    1. 12.1 Layout Guidelines
      1. 12.1.1 PCB Material
    2. 12.2 Layout Example
  13. 13Device and Documentation Support
    1. 13.1 Documentation Support
      1. 13.1.1 Related Documentation
    2. 13.2 Related Links
    3. 13.3 Receiving Notification of Documentation Updates
    4. 13.4 Community Resources
    5. 13.5 Trademarks
    6. 13.6 Electrostatic Discharge Caution
    7. 13.7 Glossary
  14. 14Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Revision History

Changes from S Revision (April 2016) to T Revision

  • Added isolation resistance for 100°C ≤ TA ≤ 125°C in the Insulation Specifications tableGo
  • Deleted the maximum transient overvoltage from VDE in the Safety-Related Certifications tableGo
  • Added the Receiving Notification of Documentation Updates and the Community Resources sectionGo

Changes from R Revision (September 2015) to S Revision

  • Changed the HBM value from ±4 V to ±4000 V and the CDM value from ±1 V to ±1000 V in the ESD Ratings tableGo
  • Moved the device power dissipation parameter from the Thermal Information table to the Power Dissipation Characteristics table Go

Changes from Q Revision (January 2015) to R Revision

  • Changed Features From: "Basic Isolation per DIN EN 60747-5-5 (VDE 0884-5) & DIN EN 61010-1" To:"Basic Insulation per DIN V VDE V 0884-10 (VDE V 0884-10):2006-12"Go
  • Changed VCC1 To VCCI, VCC2 To VCCO, GND1 To GNDI, and GND2 To GNDO, and added Notes 1 and 2 to the Simplified SchematicGo
  • Changed the CTI Test Conditions From: IEC 60112/VDE 0303 Part 1 To: DIN EN 60112 (VDE 0303-11); IEC 60112 in the Package Characteristics table Go
  • Changed section title From: DIN EN 60747-5-5 Insulation Characteristics To: DIN V VDE V 0884-10 (VDE V 0884- 10):2006-1 Insulation Characteristics(Go
  • Deleted CI - Input capacitance to ground from the Package Characteristics table Go
  • Changed RS Test Conditions From: VIO = 500 V at TS To: VIO = 500 V at TS = 150°C in the DIN V VDE V 0884-10 (VDE V 0884-10):2006-1 Insulation Characteristics tableGo
  • Changed "DIN EN 60747-5-5 & DIN EN 61010-1" To: DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 and DIN EN 61010-1 (VDE 0411-1): 2011-07 in the Regulatory Information tableGo
  • Changed title From: IEC Safety Limiting Values To: Safety Limiting ValuesGo
  • Changed VOH MIN values From: VCC - 0.8 To: VCCO - 0.8 and VCC - 0.1 To: VCCO - 0.1 in the Electrical Characteristics: VCC1 and VCC2 at 5-V Operation Go
  • Changed VOH Test Condition ISO7240 To: 3.3-V side and the MIN value From: VCC - 0.4 To VCCO -0.4 in the Electrical Characteristics: VCC1 at 5-V, VCC2 at 3.3-V OperationGo
  • Changed VOH Test Condition ISO724x (5-V side) To: 5-V side and the MIN value From: VCC - 0.8 To: VCCO - 0.8 in the Electrical Characteristics: VCC1 at 5-V, VCC2 at 3.3-V OperationGo
  • Changed VOH, Test Condition IOH = -20 µA MIN value From: VCC - 0.1 To VCCO - 0.1 in the lectrical Characteristics: VCC1 at 5-V, VCC2 at 3.3-V OperationGo
  • Changed VOH Test Condition ISO7240 To: 3.3-V side and the MIN value From: VCC - 0.4 To VCCO -0.4 in the Electrical Characteristics: VCC1 at 3.3-V, VCC2 at 5-V OperationGo
  • Changed VOH Test Condition ISO724x (5-V side) To: 5-V side and the MIN value From: VCC - 0.8 To: VCCO - 0.8 in the Electrical Characteristics: VCC1 at 3.3-V, VCC2 at 5-V OperationGo
  • Changed VOH, Test Condition IOH = -20 µA MIN value From: VCC - 0.1 To VCCO - 0.1 in the Electrical Characteristics: VCC1 at 3.3-V, VCC2 at 5-V OperationGo
  • Changed VOH MIN values From: VCC - 0.4 To: VCCO - 0.4 and VCC - 0.1 To: VCCO - 0.1 in the Electrical Characteristics: VCC1 and VCC2 at 3.3 V Operation Go
  • Changed Figure 2 title From: Thermal Derating Curve per DIN EN 60747-5-5 To: Thermal Derating Curve per VDEGo
  • Changed VCC1 To: VCCI and VCC2 To: VCCO in Common-Mode Transient Immunity Test Circuit and Voltage Waveform Go

Changes from P Revision (August 2014) to Q Revision

  • Changed the VI MAX value in the Absolute Maximum Ratings table From: 6 V To: VCC + 0.5 VGo
  • Added Note 3 to the Absolute Maximum Ratings tableGo
  • Moved TSTG - Storage From the ESD Ratings table to the Absolute Maximum Ratings table Go
  • Changed the Handling Rating table to the ESD Ratings table. Go
  • Added one row to the ISO7240CF Functions Table table. Values: X, PD, X, X, X, Undetermined Go
  • Added one row to the Device Function Table ISO724x table. Values: X, PD, X, X, Undetermined Go
  • Changed the Device I/O Schematics labels From: "ISO7240CF Input" To: "ISO7240CF Input, Disable" and From: "Enable" To: "Enable, Control" Go

Changes from O Revision (November 2012) to P Revision

  • Added Pin Configuration and Functions section, Handling Rating table, Feature Description section, Device Functional Modes, Application and Implementation section, Power Supply Recommendations section, Layout section, Device and Documentation Support section, and Mechanical, Packaging, and Orderable Information section Go
  • Changed ISO7241C minimum supply from 2.8 V to 3.15 VGo

Changes from N Revision (January 2012) to O Revision

  • Added the Safety Limiting Values sectionGo

Changes from M Revision (January 2011) to N Revision

  • Changed Feature From: Operates 3.3-V or 5-V Supplies To: Operates With 2.8-V (ISO7241C), 3.3-V or 5-V SuppliesGo
  • Added device options to VCC in the RECOMMENDED OPERATING CONDITIONS tableGo
  • Changed Table Note (1)Go
  • Changed the CTI MIN value From: ≥175 V To:≥400 VGo
  • Changed the Regulatory Information tableGo
  • Changed Table Note (1)Go
  • Changed ICC1 and ICC2 test conditions in the VCC1 and VCC2 at 5-V Electrical Characteristics: VCC1 and VCC2 at 5-V Operation tableGo
  • Changed Table Note (1)Go
  • Changed ICC1 and ICC2 test conditions in the VCC1 at 5-V, VCC2 at 3.3-V Electrical Characteristics: VCC1 at 5-V, VCC2 at 3.3-V Operation tableGo
  • Changed Table Note (1)Go
  • Changed ICC1 and ICC2 test conditions in the VCC1 at 3.3-V, VCC2 at 5-V Electrical Characteristics: VCC1 at 3.3-V, VCC2 at 5-V Operation tableGo
  • Changed Table Note (1)Go
  • Added ELECTRICAL and Switching CHARACTERISTICS tables forVCC1 and VCC2 at 2.8V (ISO722xC-only)Go
  • Changed ICC1 and ICC2 test conditions in the VCC1 and VCC2 at 3.3 V tableGo
  • Changed VCC Undervoltage Threshold vs Free-Air Temperature From VCC1 Failsafe Threshold To: VCC Undervoltage ThresholdGo

Changes from L Revision (January 2010) to M Revision

  • Changed the CSA File Number From: 1698195 To: 220991Go
  • Changed Switching Characteristic Test Circuit and Voltage Waveforms, Failsafe Delay Time Test Circuit and Voltage Waveforms, and Wake Time From Input Disable Test Circuit and Voltage WaveformsGo

Changes from K Revision (Decemberl 2009) to L Revision

  • Added CTI - Tracking resistance (comparative tracking index to the Package Characteristics tableGo
  • Added the IEC 60664-1 RATINGS TABLEGo
  • Added the IEC 60747-5-2 INSULATION CHARACTERISTIC tableGo

Changes from J Revision (April 2009) to K Revision

  • Changed the Input circuit in the DEVICE I/O SCHEMATICS illustrationGo
  • Added Note 1 to LI01), and changed the MIN value From: 8.34 To 8 mm in the Package Characteristics table Go
  • Added Note 1 to LI02), and changed the MIN value From: 8.1 To 8 mm in the Package Characteristics table Go

Changes from I Revision (December 2008) to J Revision

  • Changed ICC1 for Quiescent and 1Mbps From: 10mA To: 11mAGo
  • Changed ICC1 for Quiescent and 1Mbps From: 10mA To: 11mAGo

Changes from G Revision (July 2008) to H Revision

  • Added Device number ISO7240CF.Go
  • Added Features Bullet: Selectable Failsafe Output (ISO7240CF)Go
  • Changed description paragraph 4 text.Go
  • Changed VI in the Absolute Maximum Ratings table From: Voltage at IN, OUT, EN To: Voltage at IN, OUT, EN, DISABLE, CTRLGo
  • Added twake, Wake time from input disableGo
  • Added twake, Wake time from input disableGo
  • Added twake, Wake time from input disableGo
  • Added twake, Wake time from input disableGo

Changes from F Revision (May 2008) to G Revision

  • Changed the Package Characteristics table, line , L(IO1) MIN value from7.7mm to 8.34mmGo

Changes from E Revision (May 2008) to F Revision

  • Deleted ISO724xA devices. See SLLS905 for the ISO7240A, ISO7241A, and ISO7242A.Go
  • Changed Title From: QUAD DIGITAL ISOLATORS To: HIGH SPEED QUAD DIGITAL ISOLATORSGo
  • Changed Feature Low Jitter Content - From: 1, 25, and 150-Mbps Signaling Rate Options To: 25, and 150-Mbps Signaling Rate OptionsGo
  • Added tsk(pp) footnote.Go
  • Added tsk(o) footnote.Go
  • Added tsk(pp) footnote.Go
  • Added tsk(o) footnote.Go

Changes from D Revision (April 2008) to E Revision

  • Added Table Note (1): For the 5-V operation, VCC1 or VCC2 is specified from 4.5 V to 5.5 V. Go
  • Added Table Note (1): For the 5-V operation, VCC1 or VCC2 is specified from 4.5 V to 5.5 V Go
  • Added Table Note (1): For the 5-V operation, VCC1 or VCC2 is specified from 4.5 V to 5.5 V Go
  • Added Table Note (1): For the 5-V operation, VCC1 or VCC2 is specified from 4.5 V to 5.5 V Go

Changes from C Revision (April 2008) to D Revision

  • Added tsk(pp) Part-to-part skewGo
  • Added tsk(pp) Part-to-part skewGo
  • Added tsk(pp) Part-to-part skewGo
  • Added tsk(pp) Part-to-part skewGo
  • Changed Typical ISO724x Application Circuit, Isolated Data Acquisition System for Process Control Go

Changes from B Revision (August 2008) to C Revision

  • Deleted Min = 4.5 V and max = 5.5 V for Supply Voltage of the ROC Table.Go
  • Changed VCC Supply Voltage in the ROC Table From: 3.6 To: 5.5Go

Changes from A Revision (December 2007) to B Revision

  • Changed VCC Supply Voltage in the ROC Table From: 3.45 To: 3.6Go

Changes from * Revision (September 2007) to A Revision

  • Changed VCC Supply Voltage in the ROC Table From: 3.6 To: 3.45Go
  • Changed VCC Supply Voltage in the ROC Table From: 3 To: 3.15Go
  • Changed CIO - typ value From: 1 To: 2Go
  • Changed the Regulatory InformationGo
  • Changed CI - typ value From: 1 To: 2 in the Electrical Characteristics: VCC1 and VCC2 at 5-V OperationGo
  • Changed TBDs to actual values.Go
  • Changed CI - typ value From: 1 To: 2 in the Electrical Characteristics: VCC1 at 5-V, VCC2 at 3.3-V OperationGo
  • Changed CI - typ value From: 1 To: 2 in the Electrical Characteristics: VCC1 at 3.3-V, VCC2 at 5-V OperationGo
  • Changed typ value From: 1 To: 2 in the Electrical Characteristics: VCC1 and VCC2 at 3.3 V OperationGo
  • Changed Propagation delay max From: 22 To: 23Go
  • Changed Propagation delay max From: 46 To: 50Go
  • Changed Propagation delay max From: 28 To: 29Go
  • Changed ISO724xA/C max value From: 2.5 To: 3Go
  • Changed Propagation delay max From: 26 To: 30Go
  • Changed Propagation delay max From: 32 To: 34Go
  • Changed ISO724xA/C max value From: 3 To: 3.5Go
  • Changed ISO7240C/M RMS Supply Current vs Signaling Rate, ISO7241C/M RMS Supply Current vs Signaling Rate, and Propagation Delay vs Free-Air Temperature. Added ISO7242C/M RMS Supply Current vs Signaling Rate.Go