ZHCSKH7 November 2019 LDC1001
PRODUCTION DATA.
BIT | FIELD | TYPE | DEFAULT | DESCRIPTION |
---|---|---|---|---|
7:0 | RP Maximum | R/W | 0x0E | Maximum Sensor RP that LDC1001 needs to measure. Configures the input dynamic range of LDC1001. See Table 4 for register settings. |
REGISTER SETTING | RP MAXIMUM SENSOR DRIVE (kΩ) |
---|---|
0x00 | 3926.991 |
0x01 | 3141.593 |
0x02 | 2243.995 |
0x03 | 1745.329 |
0x04 | 1308.997 |
0x05 | 981.748 |
0x06 | 747.998 |
0x07 | 581.776 |
0x08 | 436.332 |
0x09 | 349.066 |
0x0A | 249.333 |
0x0B | 193.926 |
0x0C | 145.444 |
0x0D | 109.083 |
0x0E | 83.111 |
0x0F | 64.642 |
0x10 | 48.481 |
0x11 | 38.785 |
0x12 | 27.704 |
0x13 | 21.547 |
0x14 | 16.160 |
0x15 | 12.120 |
0x16 | 9.235 |
0x17 | 7.182 |
0x18 | 5.387 |
0x19 | 4.309 |
0x1A | 3.078 |
0x1B | 2.394 |
0x1C | 1.796 |
0x1D | 1.347 |
0x1E | 1.026 |
0x1F | 0.798 |