6.6 Electrical Characteristics
Typical values represent the most likely parametric norm at TA = TJ = 25°C, and are provided for reference purposes only. Unless otherwise specified: VIN = 12 V.
PARAMETER |
TEST CONDITIONS |
MIN(3) |
TYP(2) |
MAX(3) |
UNIT |
LM22673-5.0 |
VFB |
Feedback Voltage |
VIN = 8 V to 42 V |
4.925 |
5.0 |
5.075 |
V |
VIN = 8 V to 42 V, –40°C ≤ TJ ≤ 125°C |
4.9 |
|
5.1 |
LM22673-ADJ |
VFB |
Feedback Voltage |
VIN = 4.7 V to 42 V |
1.266 |
1.285 |
1.304 |
V |
VIN = 4.7 V to 42 V, –40°C ≤ TJ ≤ 125°C |
1.259 |
|
1.311 |
ALL OUTPUT VOLTAGE VERSIONS |
IQ |
Quiescent Current |
VFB = 5 V |
|
3.4 |
|
mA |
VFB = 5 V, –40°C ≤ TJ ≤ 125°C |
|
|
6 |
VADJ |
Current Limit Adjust Voltage |
|
|
0.8 |
|
V |
–40°C ≤ TJ ≤ 125°C |
0.65 |
|
0.9 |
ICL |
Current Limit |
|
3.4 |
4.2 |
5.3 |
A |
–40°C ≤ TJ ≤ 125°C |
3.35 |
|
5.5 |
RDS(ON) |
Switch On-Resistance |
PFM Package |
|
0.12 |
0.16 |
Ω |
PFM Package, –40°C ≤ TJ ≤ 125°C |
|
|
0.22 |
SO PowerPAD Package |
|
0.10 |
0.16 |
SO PowerPAD Package, –40°C ≤ TJ ≤ 125°C |
|
|
0.20 |
fO |
Oscillator Frequency |
|
|
500 |
|
kHz |
–40°C ≤ TJ ≤ 125°C |
400 |
|
600 |
TOFFMIN |
Minimum Off-time |
|
|
200 |
|
ns |
–40°C ≤ TJ ≤ 125°C |
100 |
|
300 |
TONMIN |
Minimum On-time |
|
|
100 |
|
ns |
IBIAS |
Feedback Bias Current |
VFB = 1.3 V (ADJ Version Only) |
|
230 |
|
nA |
ISS |
Soft-start Current |
EN Input = 0 V |
|
50 |
|
µA |
EN Input = 0 V, –40°C ≤ TJ ≤ 125°C |
30 |
|
70 |
TSD |
Thermal Shutdown Threshold |
|
|
150 |
|
°C |
(1) The absolute maximum specification of the ‘SW to GND’ applies to dc voltage. An extended negative voltage limit of –10 V applies to a pulse of up to 50 ns.
(2) Typical values represent most likely parametric norms at the conditions specified and are not ensured.
(3) MIN and MAX limits are 100% production tested at 25°C. Limits over the operating temperature range are ensured through correlation using Statistical Quality Control (SQC) methods. Limits are used to calculate TI's Average Outgoing Quality Level (AOQL).