ZHCSTL8F April 2007 – November 2023 LM25116
PRODUCTION DATA
The current limit is set by the current sense resistor value (RS) in Equation 10.
For a 5-V output, the maximum current sense signal occurs at the minimum input voltage, so RS is calculated with Equation 11.
For this example VCCX = 0 V, so VCS(TH) = 0.11 V. The current sense resistor is calculated with Equation 12.
The next lowest standard value of 10 mΩ was chosen for RS.