ZHCSD59F June 2012 – November 2017 LM34926
PRODUCTION DATA.
A coupled inductor or a flyback-type transformer is required for this topology. Energy is transferred from primary to secondary when the low-side synchronous switch of the buck converter is conducting.
The maximum inductor primary ripple current that can be tolerated without exceeding the buck switch peak current limit threshold (0.39-A minimum) is given by Equation 10.
Using the maximum peak-to-peak inductor ripple current ΔIL1 from Equation 10, the minimum inductor value is given by Equation 11.
A higher value of 47 µH is selected to insure the high-side switch current does not exceed the minimum peak current limit threshold.