SNVSCV4 September 2024 LM3645
PRODUCTION DATA
In the event that the LM3645 junction temperature reaches 125°C, the device will adjust the LED current in one of two different ways; turn off the current completely or force the current to a torch level (bits [5:4] in reg 0x13). The thermal scale back feature can be enabled or disabled as well (bit [3] in reg 0x13). The torch scale back mode is valid for flash mode and IR mode only. If the torch scaleback mode is used in torch mode, no action will occur. The force standby mode option is valid in all modes.