SNVS628H October 2009 – December 2019 LM5060
PRODUCTION DATA.
PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | ||
---|---|---|---|---|---|---|---|
VIN PIN | |||||||
IIN-EN | Input current, enabled mode | TJ = 25°C | 1.4 | mA | |||
TJ = –40°C to 125°C | 1.7 | ||||||
IIN-DIS | Input current, disabled mode | EN = 0.50 V | TJ = 25°C | 9 | µA | ||
TJ = –40°C to 125°C | 15 | ||||||
IIN-STB | Input current, standby mode | UVLO = 0.00 V | TJ = 25°C | 0.56 | mA | ||
TJ = –40°C to 125°C | 0.80 | ||||||
POREN | Power on reset threshold at VIN | VIN rising | TJ = 25°C | 5.1 | V | ||
TJ = –40°C to 125°C | 5.46 | ||||||
POREN-HYS | POREN hysteresis | VIN falling | 500 | mV | |||
OUT PIN | |||||||
IOUT-EN | OUT pin bias current, enabled | OUT = VIN, normal operation | TJ = 25°C | 8 | µA | ||
TJ = –40°C to 125°C | 5.0 | 11.0 | |||||
IOUT-DIS | OUT pin leakage current, disabled(1) | Disabled, OUT = 0 V, SENSE = VIN | 0 | μA | |||
SENSE PIN | |||||||
ISENSE | Threshold programming current | SENSE pin bias current | TJ = 25°C | 16 | µA | ||
TJ = –40°C to 125°C | 13.6 | 18.0 | |||||
VOFFSET | VDS comparator offset voltage | SENSE - OUT voltage for
fault detection |
TJ = 25°C | 0 | mV | ||
TJ = –40°C to 125°C | –7.0 | 7.0 | |||||
IRATIO | ISENSE and IOUT-EN current ratio | ISENSE / IOUT-EN | TJ = 25°C | 2.0 | |||
TJ = –40°C to 125°C | 1.70 | 2.30 | |||||
OVP INPUT | |||||||
OVPTH | OVP threshold | OVP pin threshold voltage rising | TJ = 25°C | 2.0 | V | ||
TJ = –40°C to 125°C | 1.88 | 2.12 | |||||
OVPHYS | OVP hysteresis | 240 | mV | ||||
OVPDEL | OVP delay time | Delay from OVP pin > OVPTH to GATE low | 9.6 | µs | |||
OVPBIAS | OVP pin bias current | OVP = 1.9 V | TJ = 25°C | 0 | µA | ||
TJ = –40°C to 125°C | 0.50 | ||||||
UVLO INPUT | |||||||
UVLOTH | UVLO threshold | UVLO pin threshold voltage rising | TJ = 25°C | 1.6 | V | ||
TJ = –40°C to 125°C | 1.45 | 1.75 | |||||
UVLOHYS | UVLO hysteresis | TJ = 25°C | 180 | mV | |||
TJ = –40°C to 125°C | 120 | 230 | |||||
UVLOBIAS | UVLO pin pull-down current | TJ = 25°C | 5.5 | µA | |||
TJ = –40°C to 125°C | 3.8 | 7.2 | |||||
EN INPUT | |||||||
ENTHH | High-level input voltage | TJ = –40°C to 125°C | 2.00 | V | |||
ENTHL | Low-level input voltage | TJ = –40°C to 125°C | 0.80 | V | |||
ENHYS | EN threshold hysteresis | 200 | mV | ||||
ENBIAS | EN pin pull-down current | TJ = 25°C | 6 | µA | |||
TJ = –40°C to 125°C | 8.0 | ||||||
GATE CONTROL (GATE PIN) | |||||||
IGATE | Gate charge (sourcing) current, on state | On-state | TJ = 25°C | 24 | µA | ||
TJ = –40°C to 125°C | 17 | 31 | |||||
IGATE-OFF | Gate discharge (sinking) current, off state | UVLO = 0.00 V | 2.2 | mA | |||
IGATE-FLT | Gate discharge (sinking) current, fault state | OUT < SENSE | 80 | mA | |||
VGATE | Gate output voltage in normal operation | GATE - VIN voltage
GATE pin open |
TJ = 25°C | 12 | V | ||
TJ = –40°C to 125°C | 10 | 14 | |||||
VGATE-TH | VGS status comparator threshold voltage | GATE - OUT threshold voltage for TIMER voltage reset and
TIMER current change |
TJ = 25°C | 5 | V | ||
TJ = –40°C to 125°C | 3.50 | 6.50 | |||||
VGATE-CLAMP | Zener clamp between GATE pin and OUT pin | IGATE-CLAMP = 0.1 mA | 16.8 | V | |||
TIMER (TIMER PIN) | |||||||
VTMRH | Timer fault threshold | TIMER pin voltage rising | 2.0 | V | |||
VTMRL | Timer re-enable threshold | TIMER pin voltage falling | 0.30 | V | |||
ITIMERH | Timer charge current for VDS fault | TIMER charge current
after start-up VGS = 6.5 V |
TJ = 25°C | 11 | µA | ||
TJ = –40°C to 125°C | 8.5 | 13.0 | |||||
ITIMERL | Timer start-up charge current | TIMER charge current
during start-up VGS = 3.5 V |
TJ = 25°C | 6 | µA | ||
TJ = –40°C to 125°C | 4.0 | 7.0 | |||||
ITIMERR | Timer reset discharge current | TIMER pin = 1.5 V | TJ = 25°C | 6 | mA | ||
TJ = –40°C to 125°C | 4.4 | 8.2 | |||||
tFAULT | Fault to GATE low delay | TIMER pin > 2.0 V
No load on GATE pin |
5 | µs | |||
POWER GOOD (nPGD PIN) | |||||||
PGDVOL | Output low voltage | ISINK = 2 mA | TJ = 25°C | 80 | mV | ||
TJ = –40°C to 125°C | 205 | ||||||
PGDIOH | Off leakage current | VnPGD = 10 V | TJ = 25°C | 0.02 | µA | ||
TJ = –40°C to 125°C | 1.00 |