6.1 Absolute Maximum Ratings
Over operating free-air temperature range (unless otherwise noted)(1)
|
MIN |
MAX |
UNIT |
Input |
VIN, CSP, CSN |
–0.3 |
75 |
V |
BST to SW, FB, MODE, UVLO, OPT, VCC(2) |
–0.3 |
15 |
V |
SW |
–5 |
105 |
V |
BST |
–0.3 |
115 |
V |
SS, SLOPE, SYNCIN/RT |
–0.3 |
7 |
V |
CSP to CSN, PGND |
–0.3 |
0.3 |
V |
Output(3) |
HO to SW |
–0.3 |
BST to SW + 0.3 |
V |
LO |
–0.3 |
VCC + 0.3 |
V |
COMP, RES, SYNCOUT |
–0.3 |
7 |
V |
Thermal |
Junction temperature, TJ |
–40 |
150 |
°C |
Storage temperature, Tstg |
–55 |
150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions are not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. Unless otherwise specified, all voltages are referenced to AGND pin.
(3) All output pins are not specified to have an external voltage applied.