ZHCSOB0A july 2021 – august 2023 LM5157
PRODUCTION DATA
An internal thermal shutdown turns off the VCC regulator, disables switching, and pulls down the SS when the junction temperature exceeds the thermal shutdown threshold (TTSD). After the junction temperature is decreased by 15°C, the VCC regulator is enabled again and the device performs a soft start.