6.3 Recommended Operating Conditions(1)
Over operating free-air temperature range (unless otherwise noted)
|
MIN |
NOM |
MAX |
UNIT |
VIN input voltage |
4.5 |
|
100 |
V |
IO output current |
|
|
1 |
A |
External VCC bias voltage |
9 |
|
13 |
V |
Operating junction temperature(2)
|
–40 |
|
150 |
°C |
(1) Recommended Operating Conditions are conditions under the device is intended to be functional. For specifications and test conditions, see
Electrical Characteristics