ZHCSFE2A August 2016 – November 2017 LM5161-Q1
PRODUCTION DATA.
The output capacitor is selected to limit the capacitive ripple at the output of the regulator. Maximum capacitive ripple is observed at maximum input voltage. The output capacitance required for a ripple voltage ∆VO across the capacitor is given by Equation 16.