6.1 Absolute Maximum Ratings(1)(2)
|
MIN |
MAX |
UNIT |
Input voltage |
VIN to AGND |
–0.3 |
100 |
V |
EN/UVLO to AGND |
–0.3 |
100 |
RON to AGND |
–0.3 |
100 |
BST to AGND |
–0.3 |
114 |
VCC to AGND |
–0.3 |
14 |
FPWM to AGND |
–0.3 |
14 |
SS to AGND |
–0.3 |
7 |
FB to AGND |
–0.3 |
7 |
Output voltage |
BST to SW |
–0.3 |
14 |
V |
BST to VCC |
|
100 |
SW to AGND |
–1.5 |
100 |
SW to AGND (20-ns transient) |
–3 |
|
Maximum junction temperature (3)
|
|
–40 |
150 |
°C |
Storage temperature Tstg
|
|
–65 |
150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions . Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/ Distributors for availability and specifications.
(3) High junction temperatures degrade operating lifetimes. Operating lifetime is de-rated for junction temperatures greater than 125°C.