ZHCSNL2A February 2022 – May 2022 LM74502-Q1 , LM74502H-Q1
PRODUCTION DATA
Resistors R1 and R2 connected in series is used to program the overvoltage threshold. Connecting R1 to VIN provides overvoltage cutoff and switching the connection to VOUT provides overvoltage clamp response. The resistor values required for setting the overvoltage threshold VOV to 37 V are calculated by solving Equation 3
Based on application use case, overvoltage threshold can be set at the lower voltage as it enables lower rated downstream components, thus providing solution size and lower cost benefit.