SNVS090G May 2004 – June 2020 LM341
PRODUCTION DATA.
PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | ||
---|---|---|---|---|---|---|---|
VO | Output voltage | IL = 500 mA | 14.4 | 15 | 15.6 | V | |
IL = 5 mA to 500 mA, PD ≤ 7.5 W, VIN = 18 V to 30 V, TJ = –40°C to 125°C | 14.25 | 15 | 15.75 | ||||
VRLINE | Line regulation | VIN = 17.6 V to 30 V | IL = 100 mA | 150 | mV | ||
IL = 500 mA | 300 | ||||||
VRLOAD | Load regulation | IL = 5 mA to 500 mA | 300 | mV | |||
IQ | Quiescent current | IL = 500 mA | 4 | 10 | mA | ||
ΔIQ | Quiescent current change | IL = 5 mA to 500 mA | 0.5 | mA | |||
VIN = 18 V to 30 V, IL = 500 mA | 1 | ||||||
Vn | Output noise voltage | f = 10 Hz to 100 kHz | 90 | µV | |||
ΔVIN | Ripple rejection | f = 120 Hz, IL = 500 mA | 69 | dB | |||
VIN | Input voltage required to maintain line regulation | IL = 500 mA | 17.6 | V | |||
ΔVO | Long-term stability | IL = 500 mA, TJ = –40°C to 125°C | 60 | mV/khrs |