see (1)(2)(3)(5)
|
MIN |
MAX |
UNIT |
VCC |
Supply Voltage (4) |
–0.3 |
3.6 |
V |
VIN |
Input Voltage |
–0.3 |
(VCC + 0.3) |
V |
TL |
Lead Temperature (solder 4
seconds) |
|
260 |
°C |
IIN |
Differential Input Current
(CLKinX/X*) |
|
±5 |
mA |
MSL |
Moisture Sensitivity Level |
|
3 |
|
Tstg |
Storage Temperature |
–65 |
150 |
°C |
(1) Operation outside the Absolute Maximum Ratings may cause
permanent device damage. Absolute Maximum Ratings do not imply functional operation
of the device at these or any other conditions beyond those listed under Recommended
Operating Conditions. If used outside the Recommended Operating Conditions
but within the Absolute Maximum Ratings, the device may not be fully functional,
and this may affect device reliability, functionality, performance, and shorten the device
lifetime.
(2) This device is a high performance RF integrated circuit with an ESD
rating up to 2.5 kV Human Body Model, up to 250 V Machine Model and up to 1,250 V Charged
Device Model and is ESD sensitive. Handling and assembly of this device should only be
done at ESD-free workstations.
(3) Stresses in excess of the absolute maximum ratings can cause permanent
or latent damage to the device. These are absolute stress ratings only. Functional
operation of the device is only implied at these or any other conditions in excess of
those given in the operation sections of the data sheet. Exposure to absolute maximum
ratings for extended periods can adversely affect device reliability.
(4) Never to exceed 3.6 V.
(5) If Military/Aerospace specified devices are required, please contact
the Texas Instruments Sales Office/Distributors for availability and specifications.