ZHCSN30C December 2020 – March 2022 LMP7704-SP
PRODUCTION DATA
Take care to minimize the loop area formed by the bypass capacitor connection between supply pins and ground. Use a ground plane underneath the device; best practice is for any bypass components to ground to have a nearby via to the ground plane. The optimum bypass capacitor placement is closest to the corresponding supply pin. Use of thicker traces from the bypass capacitors to the corresponding supply pins lowers the power-supply inductance and provides a more stable power supply.
To minimize stray parasitics, place the feedback components as close as possible to the device.