ZHCSAU0B April 2012 – October 2015 LMP91002
PRODUCTION DATA.
The LMP91002 is intended for use in portable devices, so the power consumption is as low as possible in order to ensure a long battery life. The total power consumption for the LMP91002 is below 10 µA at 3.3-V average over time, (this excludes any current drawn from any pin). A typical usage of the LMP91002 is in a portable gas detector and its power consumption is summarized in Table 7. This has the following assumptions:
This results in an average power consumption of approximately 7.8 µA. This can potentially be further reduced, by using the Standby mode between gas measurements. It may even be possible, depending on the sensor used, to go into deep sleep for some time between measurements, further reducing the average power consumption.
DEEP SLEEP | STANDBY | 3-LEAD AMPEROMETRIC CELL | TOTAL | |
---|---|---|---|---|
Current consumption (µA) typical value | 0.6 | 6.5 | 10 | |
Time ON (%) | 0 | 60 | 39 | |
Average (µA) | 0 | 3.9 | 3.9 | 7.8 |
Notes | ||||
A1 | OFF | ON | ON | |
TIA | OFF | OFF | ON | |
I2C interface | ON | ON | ON |