7.3 Recommended Operating Conditions
Over the recommended operating junction temperature range of –40°C to +150°C (unless otherwise noted).
|
MIN |
NOM |
MAX |
UNIT |
Input voltage after start-up(1)
|
3.9 |
|
36 |
V |
Output adjustment for LMS3655(2)
|
3.3 |
|
6 |
V |
Extended output adjustment for LMS3655(3)(4)
|
1 |
|
20
|
V |
Load current for LMS3655 |
|
|
5.5 |
A |
Operating ambient temperature(5)
|
–40 |
|
125 |
°C |
(1) An extended input voltage range to 3.5 V is possible; see
System Characteristics table. See
Input UVLO for start-up conditions.
(2) The output voltage must not be allowed to fall below zero volts during normal operation.
(3) Operation below 3.3 V and above 6 V may require changes to the typical application schematic, operation may not be possible over the full input voltage range, and some system specifications will not be achieved for this extended output voltage range. Consult the factory for further information.
(4) Operation above 15 V requires the BIAS pin grounded or powered by an external source. A maximum of 16 V can be sustained on the BIAS pin.
(5) High junction temperatures degrade operating lifetime.