6.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted) (1)(2)
|
MIN |
MAX |
UNIT |
|
VIN, RON to GND |
–0.3 |
43.5 |
V |
|
EN, FB, SS to GND |
–0.3 |
7 |
V |
TJ |
Junction temperature |
|
150 |
°C |
|
Peak reflow case temperature (30 s) |
|
245 |
°C |
Tstg |
Storage temperature |
–65 |
150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
6.5 Electrical Characteristics
Limits in standard type are for TJ = 25°C only; limits in boldface type apply over the junction temperature (TJ) range of –40°C to +125°C. Minimum and maximum limits are ensured through test, design or statistical correlation. Typical values represent the most likely parametric norm at TJ = 25°C, and are provided for reference purposes only. Unless otherwise stated the following conditions apply: VVIN = 24 V, VVOUT = 3.3 V
PARAMETER |
TEST CONDITIONS |
MIN(1) |
TYP(2) |
MAX(1) |
UNIT |
ENABLE CONTROL(3) |
VEN |
EN threshold trip point |
VEN rising |
|
|
1.18 |
|
V |
–40°C ≤ TJ ≤ 125°C |
1.1 |
|
1.25 |
VEN-HYS |
EN threshold hysteresis |
VEN falling |
|
90 |
|
mV |
SOFT-START |
ISS |
SS source current |
VSS = 0 V |
|
|
8 |
|
µA |
–40°C ≤ TJ ≤ 125°C |
5 |
|
11 |
ISS-DIS |
SS discharge current |
|
|
-200 |
|
µA |
CURRENT LIMIT |
ICL |
Current limit threshold |
d.c. average |
|
|
2.6 |
|
A |
–40°C ≤ TJ ≤ 125°C |
2.3 |
|
3.65 |
ON/OFF TIMER |
tON-MIN |
ON timer minimum pulse width |
|
|
150 |
|
ns |
tOFF |
OFF timer pulse width |
|
|
260 |
|
ns |
REGULATION AND OVERVOLTAGE COMPARATOR |
VFB |
In-regulation feedback voltage |
VSS > 0.8 V, IO = 2 A |
|
|
0.795 |
|
V |
–40°C ≤ TJ ≤ 125°C |
0.775 |
|
0.815 |
VSS >+ 0.8 V, IO = 10 mA |
0.786 |
0.802 |
0.818 |
V |
VFB-OV |
Feedback over-voltage protection threshold |
|
|
0.92 |
|
V |
IFB |
Feedback input bias current |
|
|
5 |
|
nA |
IQ |
Non-switching input current |
VFB = 0.86 V |
|
1 |
|
mA |
ISD |
Shutdown quiescent current |
VEN = 0 V |
|
25 |
|
μA |
THERMAL CHARACTERISTICS |
TSD |
Thermal shutdown |
Rising |
|
165 |
|
°C |
TSD-HYST |
Thermal shutdown hysteresis |
Falling |
|
15 |
|
°C |
PERFORMANCE PARAMETERS |
ΔVO |
Output voltage ripple |
|
|
8 |
|
mVP-P |
ΔVO/ΔVIN |
Line regulation |
12 V ≤ VVIN ≤ 42 V, IO = 2 A |
|
0.01% |
|
|
ΔVO/IOUT |
Load regulation |
VVIN = 24 V |
|
1.5 |
|
mV/A |
η |
Efficiency |
VVIN = 24 V, VO = 3.3 V, IO = 1 A |
|
86% |
|
|
VVIN = 24 V, VO = 3.3 V, IO = 2 A |
|
85% |
|
|
(1) Minimum and maximum limits are 100% production tested at 25°C. Limits over the operating temperature range are ensured through correlation using Statistical Quality Control (SQC) methods. Limits are used to calculate Average Outgoing Quality Level (AOQL).
(2) Typical numbers are at 25°C and represent the most likely parametric norm.
(3) EN 55022:2006, +A1:2007, FCC Part 15 Subpart B: 2007. See
AN-2024 LMZ1420x / LMZ1200x Evaluation Board (
SNVA422) and layout for information on device under test.