INITIALIZATION: The device enters into INITIALIZATION mode when EN = H. In this mode, all the registers are reset. Entry can also be from any state, if the RESET (register) = FFh or UVLO is active.
NORMAL: The device enters the NORMAL mode when Chip_EN (register) = 1.
ICC is 10mA (typical).
POWER SAVE: The device automatically enters the POWER SAVE mode when
Power_Save_EN (register) = 1 and all the LEDs are off for a duration of >
30ms. In POWER SAVE mode, analog blocks are disabled to minimize power
consumption, but the registers retain the data and keep it available via
I2C. ICC is 10µA (typical). In case of any
I2C command to this device, it returns to the NORMAL mode.
SHUTDOWN: The device enters into SHUTDOWN mode from all states on
VCC power up or when EN = L. ICC is < 1µA
(maximum).
STANDBY: The device enters the STANDBY mode when Chip_EN (register) = 0.
In this mode, all the OUTx pins are shut down, but the registers retain the data
and keep it available via I2C. STANDBY is the low-power-consumption
mode, when all circuit functions are disabled. ICC is 10µA
(typical).
THERMAL SHUTDOWN: The device automatically enters the THERMAL SHUTDOWN mode when the junction temperature exceeds 160°C (typical). In this mode, all the OUTx outputs are shut down. If the junction temperature decreases below 145°C (typical), the device returns to the NORMAL mode.