Figure 8-13 lists the device functional modes.
- Initialization: The device enters into Initialization when Vcc goes down to UVLO voltage. In this mode, all the registers are reset. Entry can also be from any state.
- Normal: The device enters the normal mode when Vcc is higher than UVLO threshold. The display process is shown as below in normal mode.
- Power Saving: The device automatically enters and gets out from the
power save mode when it detects the condition PSin and PSout. In this mode,
all channels will turn off. PSin: after the device detects that the display
data of the next frame all equal to zero, it will enter to power save mode
when the VSYNC comes. PSout: after the device detects that there is non-zero
display data of the next frame, it will get out from power save mode
immediately.
- IREF Resistor Short Protection: The device automatically enters and gets
out from the IREF Resistor Short Protection mode when it detects the
condition ISPin and ISPout. In this mode, all channels will turn off. ISPin:
the device detects that the reference voltage is smaller than 0.195 V.
ISPout: the device detects that the reference voltage is larger than 0.325
V.
- Thermal Shutdown: The device automatically enters and gets out from the
Thermal Shutdown mode when it detects the condition TSDin and TSDout. In
this mode, all channels will turn off. TSDin: the device detects that the
junction temperature exceeds 170° C. TSDout: the device detects that the
junction temperature is below 155° C.