8.4.1 Modes of Operation
SHUTDOWN:The V(NRST) voltage is below threshold level. All switch, reference, control and bias circuitry of the LP8758 device are turned off.
WAIT-ON:The V(NRST) voltage is above threshold level. The reference and bias circuitry are enabled. The regulator of the LP8758 device is turned off.
READ OTP:The main supply voltage V(VANA) is above VANAUVLO level and V(NRST) voltage is above threshold level. The regulator is disabled and the reference and bias circuitry of the LP8758 are enabled. The OTP bits are loaded to registers.
STANDBY:The main supply voltage V(VANA) is above VANAUVLO level and V(NRST) voltage is above threshold level. The regulator is disabled and the reference, control and bias circuitry of the LP8758 are enabled. All registers can be read or written by the host processor via the system serial interface. The regulator can be enabled if needed.
ACTIVE:The main supply voltage V(VANA) is above VANAUVLO level and V(NRST) voltage is above threshold level. At least one regulated DC-DC converter is enabled. All registers can be read or written by the host processor via the system serial interface.
The operating modes and transitions between the modes are shown in Figure 14.