Table 8-6 summarizes the PGx behavior in different application scenarios, for the gated and continuous operating modes.
STATUS / USE CASE | CONDITION | PGx SIGNAL(1)(2) | |
---|---|---|---|
GATED MODE PGx_MODE = 0 |
CONTINUOUS MODE PGx_MODE = 1 |
||
Device start-up | Until device state is STANDBY | Low | Low |
Converter not selected for PGx monitoring | EN_PGOOD_x = 0 | OK | OK |
Converter selected for PGx monitoring and disabled by host | BUCKx_EN / BOOST_EN = 0 OR (Pin ctrl AND EN = 0) |
OK | OK |
Converter start-up delay ongoing | EN = 1 | OK | NOK |
Converter start-up until valid output voltage reached | Valid output voltage reached in 800 µs | OK | NOK |
Converter start-up until valid output voltage reached | Valid output voltage not reached at 800 µs | NOK | NOK |
Output voltage within window limits after start-up | Must be inside limits longer than debounce time | OK | OK |
Output voltage spikes (over/undervoltage) | If spikes are outside voltage monitoring threshold(s) longer than debounce time | NOK | NOK |
Voltage setting change, output voltage ramp | OK (if new voltage reached in 800 µs) NOK after 800 µs (if new voltage not reached at 800 µs) |
NOK | |
Output voltage within window limits after voltage change | Must be inside limits longer than debounce time | OK | OK |
Converter shutdown delay ongoing | OK | OK | |
Buck converter disabled by host, slew-rate controlled ramp down ongoing | OK | OK | |
Converter disabled by host, pulldown resistor active (if selected) | OK | OK | |
Converter short-circuit interrupt pending (converter selected for PGx monitoring) | Faulty converter disabled by short-circuit
detection BUCKx_SC_INT / BOOST_SC_INT = 1 |
NOK | NOK |
Thermal shutdown interrupt pending | Converters disabled by thermal shutdown
detection TDIE_SD_INT = 1 |
NOK | NOK |
Input (VANA) overvoltage interrupt pending | Converters disabled by overvoltage detection OVP_INT = 1 |
NOK | NOK |
Supply voltage below VANAUVLO | Low | Low |