over operating free-air temperature range (unless otherwise noted)(1) | MIN | MAX | UNIT |
---|
| VCC to GND | –0.3 | 6 | V |
| V+ to GND | –0.3 | 7 |
| V– to GND | 0.3 | –7 |
| V+ + |V–|(2) | | 13 |
VI | Input voltage | DIN, EN, FORCEOFF , and FORCEON to GND | –0.3 | 6 | V |
RIN to GND | | ±25 |
VO | Output voltage | DOUT to GND | | ±13.2 | V |
ROUT to GND | –0.3 | VCC + 0.3 |
TJ | Junction temperature(3) | | 150 | °C |
Tstg | Storage temperature range | –65 | 150 |
(1) Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If used outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not be fully functional, and this may affect device reliability, functionality, performance, and shorten the device lifetime.
(2) V+ and V– can have maximum magnitudes of 7 V, but their absolute difference cannot exceed 13 V.
(3) Maximum power dissipation is a function of TJ(max), RθJA, and TA. The maximum allowable power dissipation at any allowable ambient temperature is PD = (TJ(max) – TA) / RθJA. Operating at the absolute maximum TJ of 150°C can affect reliability.