SNOS405B November 1999 – May 2017 MAX660
PRODUCTION DATA.
PIN | I/O | DESCRIPTION | ||
---|---|---|---|---|
NAME | NO. | VOLTAGE INVERTER | VOLTAGE DOUBLER | |
CAP+ | 2 | Power | Connect this pin to the positive terminal of charge-pump capacitor. | Same as inverter |
CAP– | 4 | Power | Connect this pin to the negative terminal of charge-pump capacitor. | Same as inverter |
FC | 1 | Input | Frequency control for internal oscillator: FC = open, ƒOSC = 10 kHz (typical); FC = V+, ƒOSC = 80 kHz (typical); FC has no effect when OSC pin is driven externally |
Same as inverter |
GND | 3 | Ground | Power supply ground input. | Power supply positive voltage input |
LV | 6 | Input | Low-voltage operation input. Tie LV to GND when input voltage is less than 3.5 V. Above 3.5 V, LV can be connected to GND or left open. When driving OSC with an external clock, LV must be connected to GND. | LV must be tied to OUT. |
OSC | 7 | Input | Oscillator control input. OSC is connected to an internal 15-pF capacitor. An external capacitor can be connected to slow the oscillator. Also, an external clock can be used to drive OSC. | Same as inverter except that OSC cannot be driven by an external clock |
OUT | 5 | Power | Negative voltage output | Positive supply ground input |
V+ | 8 | Power | Power supply positive voltage input | Positive voltage output |