ZHCSAU5E September 2012 – September 2018 MSP430F6745 , MSP430F6746 , MSP430F6747 , MSP430F6748 , MSP430F6749 , MSP430F6765 , MSP430F6766 , MSP430F6767 , MSP430F6768 , MSP430F6769 , MSP430F6775 , MSP430F6776 , MSP430F6777 , MSP430F6778 , MSP430F6779
PRODUCTION DATA.
PARAMETER | MIN | MAX | UNIT | |
---|---|---|---|---|
tSwitch | Time from occurrence of trigger (SVM or software) to "new" supply connected to system supplies | 100 | ns | |
tRecover | "Recovery time" after a switch over took place. During that time no further switching takes place. | 170 | 480 | µs |