Table 5-12 eUSCI (UART Mode) Switching Characteristics
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER |
TEST CONDITIONS |
VCC |
TYP |
UNIT |
tt |
UART receive deglitch time (1) |
UCGLITx = 0 |
2 V, 3 V |
12 |
ns |
UCGLITx = 1 |
40 |
UCGLITx = 2 |
68 |
UCGLITx = 3 |
110 |