ZHCSCG3C May   2014  – December 2017 MSP430FR5720 , MSP430FR5721 , MSP430FR5722 , MSP430FR5723 , MSP430FR5724 , MSP430FR5725 , MSP430FR5726 , MSP430FR5727 , MSP430FR5728 , MSP430FR5729

PRODUCTION DATA.  

  1. 1器件概述
    1. 1.1 特性
    2. 1.2 应用范围
    3.     4
    4. 1.3 说明
    5. 1.4 功能方框图
  2. 2修订历史记录
  3. 3Device Comparison
    1. 3.1 Related Products
  4. 4Terminal Configuration and Functions
    1. 4.1 Pin Diagram – RHA Package – MSP430FR5721, MSP430FR5723, MSP430FR5725, MSP430FR5727, MSP430FR5729
    2. 4.2 Pin Diagram – DA Package – MSP430FR5721, MSP430FR5723, MSP430FR5725, MSP430FR5727, MSP430FR5729
    3. 4.3 Pin Diagram – RGE Package – MSP430FR5720, MSP430FR5722, MSP430FR5724, MSP430FR5726, MSP430FR5728
    4. 4.4 Pin Diagram – PW Package – MSP430FR5720, MSP430FR5722, MSP430FR5724, MSP430FR5726, MSP430FR5728
    5. 4.5 Signal Descriptions
      1. Table 4-1 Signal Descriptions
  5. 5Specifications
    1. 5.1  Absolute Maximum Ratings
    2. 5.2  ESD Ratings
    3. 5.3  Recommended Operating Conditions
    4. 5.4  Active Mode Supply Current Into VCC Excluding External Current
    5. 5.5  Low-Power Mode Supply Currents (Into VCC) Excluding External Current
    6. 5.6  Thermal Resistance Characteristics
    7. 5.7  Schmitt-Trigger Inputs – General-Purpose I/O (P1.0 to P1.7, P2.0 to P2.7, P3.0 to P3.7, P4.0 to P4.1, PJ.0 to PJ.5, RST/NMI)
    8. 5.8  Inputs – Ports P1 and P2 (P1.0 to P1.7, P2.0 to P2.7)
    9. 5.9  Leakage Current – General-Purpose I/O (P1.0 to P1.7, P2.0 to P2.7, P3.0 to P3.7, P4.0 to P4.1, PJ.0 to PJ.5, RST/NMI)
    10. 5.10 Outputs – General-Purpose I/O (P1.0 to P1.7, P2.0 to P2.7, P3.0 to P3.7, P4.0 to P4.1, PJ.0 to PJ.5)
    11. 5.11 Output Frequency – General-Purpose I/O (P1.0 to P1.7, P2.0 to P2.7, P3.0 to P3.7, P4.0 to P4.1, PJ.0 to PJ.5)
    12. 5.12 Typical Characteristics – Outputs
    13. 5.13 Crystal Oscillator, XT1, Low-Frequency (LF) Mode
    14. 5.14 Crystal Oscillator, XT1, High-Frequency (HF) Mode
    15. 5.15 Internal Very-Low-Power Low-Frequency Oscillator (VLO)
    16. 5.16 DCO Frequencies
    17. 5.17 MODOSC
    18. 5.18 PMM, Core Voltage
    19. 5.19 PMM, SVS, BOR
    20. 5.20 Wake-up Times From Low-Power Modes
    21. 5.21 Timer_A
    22. 5.22 Timer_B
    23. 5.23 eUSCI (UART Mode) Clock Frequency
    24. 5.24 eUSCI (UART Mode)
    25. 5.25 eUSCI (SPI Master Mode) Clock Frequency
    26. 5.26 eUSCI (SPI Master Mode)
    27. 5.27 eUSCI (SPI Slave Mode)
    28. 5.28 eUSCI (I2C Mode)
    29. 5.29 10-Bit ADC, Power Supply and Input Range Conditions
    30. 5.30 10-Bit ADC, Timing Parameters
    31. 5.31 10-Bit ADC, Linearity Parameters
    32. 5.32 REF, External Reference
    33. 5.33 REF, Built-In Reference
    34. 5.34 REF, Temperature Sensor and Built-In VMID
    35. 5.35 Comparator_D
    36. 5.36 FRAM
    37. 5.37 JTAG and Spy-Bi-Wire Interface
  6. 6Detailed Description
    1. 6.1  Functional Block Diagrams
    2. 6.2  CPU
    3. 6.3  Operating Modes
    4. 6.4  Interrupt Vector Addresses
    5. 6.5  Memory Organization
    6. 6.6  Bootloader (BSL)
    7. 6.7  JTAG Operation
      1. 6.7.1 JTAG Standard Interface
      2. 6.7.2 Spy-Bi-Wire Interface
    8. 6.8  FRAM
    9. 6.9  Memory Protection Unit (MPU)
    10. 6.10 Peripherals
      1. 6.10.1  Digital I/O
      2. 6.10.2  Oscillator and Clock System (CS)
      3. 6.10.3  Power-Management Module (PMM)
      4. 6.10.4  Hardware Multiplier (MPY)
      5. 6.10.5  Real-Time Clock (RTC_B)
      6. 6.10.6  Watchdog Timer (WDT_A)
      7. 6.10.7  System Module (SYS)
      8. 6.10.8  DMA Controller
      9. 6.10.9  Enhanced Universal Serial Communication Interface (eUSCI)
      10. 6.10.10 TA0, TA1
      11. 6.10.11 TB0, TB1, TB2
      12. 6.10.12 ADC10_B
      13. 6.10.13 Comparator_D
      14. 6.10.14 CRC16
      15. 6.10.15 Shared Reference (REF)
      16. 6.10.16 Embedded Emulation Module (EEM)
      17. 6.10.17 Peripheral File Map
    11. 6.11 Input/Output Diagrams
      1. 6.11.1  Port P1 (P1.0 to P1.2) Input/Output With Schmitt Trigger
      2. 6.11.2  Port P1 (P1.3 to P1.5) Input/Output With Schmitt Trigger
      3. 6.11.3  Port P1 (P1.6 and P1.7) Input/Output With Schmitt Trigger
      4. 6.11.4  Port P2 (P2.0 to P2.2) Input/Output With Schmitt Trigger
      5. 6.11.5  Port P2 (P2.3 and P2.4) Input/Output With Schmitt Trigger
      6. 6.11.6  Port P2 (P2.5 and P2.6) Input/Output With Schmitt Trigger
      7. 6.11.7  Port P2 (P2.7) Input/Output With Schmitt Trigger
      8. 6.11.8  Port P3 (P3.0 to P3.3) Input/Output With Schmitt Trigger
      9. 6.11.9  Port P3 (P3.4 to P3.6) Input/Output With Schmitt Trigger
      10. 6.11.10 Port Port P3 (P3.7) Input/Output With Schmitt Trigger
      11. 6.11.11 Port Port P4 (P4.0) Input/Output With Schmitt Trigger
      12. 6.11.12 Port Port P4 (P4.1) Input/Output With Schmitt Trigger
      13. 6.11.13 Port Port PJ (PJ.0 to PJ.3) JTAG Pins TDO, TMS, TCK, TDI/TCLK, Input/Output With Schmitt Trigger or Output
      14. 6.11.14 Port Port PJ (PJ.4 and PJ.5) Input/Output With Schmitt Trigger
    12. 6.12 Device Descriptors (TLV)
  7. 7器件和文档支持
    1. 7.1  开始使用
    2. 7.2  Device Nomenclature
    3. 7.3  工具和软件
    4. 7.4  文档支持
    5. 7.5  相关链接
    6. 7.6  社区资源
    7. 7.7  商标
    8. 7.8  静电放电警告
    9. 7.9  出口管制提示
    10. 7.10 术语表
  8. 8机械、封装和可订购信息

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Device Descriptors (TLV)

Table 6-53 and Table 6-54 list the complete contents of the device descriptor tag-length-value (TLV) structure for each device type.

Table 6-53 Device Descriptor Table (1)

DESCRIPTIONADDRESSVALUE
FR5729FR5728FR5727FR5726FR5725
Info Block Info length 01A00h 05h 05h 05h 05h 05h
CRC length 01A01h 05h 05h 05h 05h 05h
CRC value 01A02h per unit per unit per unit per unit per unit
01A03h per unit per unit per unit per unit per unit
Device ID 01A04h 7Bh 7Ah 79h 74h 78h
Device ID 01A05h 80h 80h 80h 81h 80h
Hardware revision 01A06h per unit per unit per unit per unit per unit
Firmware revision 01A07h per unit per unit per unit per unit per unit
Die Record Die Record Tag 01A08h 08h 08h 08h 08h 08h
Die record length 01A09h 0Ah 0Ah 0Ah 0Ah 0Ah
Lot/wafer ID 01A0Ah per unit per unit per unit per unit per unit
01A0Bh per unit per unit per unit per unit per unit
01A0Ch per unit per unit per unit per unit per unit
01A0Dh per unit per unit per unit per unit per unit
Die X position 01A0Eh per unit per unit per unit per unit per unit
01A0Fh per unit per unit per unit per unit per unit
Die Y position 01A10h per unit per unit per unit per unit per unit
01A11h per unit per unit per unit per unit per unit
Test results 01A12h per unit per unit per unit per unit per unit
01A13h per unit per unit per unit per unit per unit
ADC10 Calibration ADC10 calibration tag 01A14h 13h 13h 13h 05h 13h
ADC10 calibration length 01A15h 10h 10h 10h 10h 10h
ADC gain factor 01A16h per unit per unit NA NA per unit
01A17h per unit per unit NA NA per unit
ADC offset 01A18h per unit per unit NA NA per unit
01A19h per unit per unit NA NA per unit
ADC 1.5-V reference
Temp. sensor 30°C
01A1Ah per unit per unit NA NA per unit
01A1Bh per unit per unit NA NA per unit
ADC 1.5-V reference
Temp. sensor 85°C
01A1Ch per unit per unit NA NA per unit
01A1Dh per unit per unit NA NA per unit
ADC 2.0-V reference
Temp. sensor 30°C
01A1Eh per unit per unit NA NA per unit
01A1Fh per unit per unit NA NA per unit
ADC 2.0-V reference
Temp. sensor 85°C
01A20h per unit per unit NA NA per unit
01A21h per unit per unit NA NA per unit
ADC 2.5-V reference
Temp. sensor 30°C
01A22h per unit per unit NA NA per unit
01A23h per unit per unit NA NA per unit
ADC 2.5-V reference
Temp. sensor 85°C
01A24h per unit per unit NA NA per unit
01A25h per unit per unit NA NA per unit
REF Calibration REF calibration tag 01A26h 12h 12h 12h 12h 12h
REF calibration length 01A27h 06h 06h 06h 06h 06h
REF 1.5-V Reference 01A28h per unit per unit per unit per unit per unit
01A29h per unit per unit per unit per unit per unit
REF 2.0-V reference 01A2Ah per unit per unit per unit per unit per unit
01A2Bh per unit per unit per unit per unit per unit
REF 2.5-V reference 01A2Ch per unit per unit per unit per unit per unit
01A2Dh per unit per unit per unit per unit per unit
NA = Not applicable

Table 6-54 Device Descriptor Table (1)

DESCRIPTIONADDRESSVALUE
FR5724FR5723FR5722FR5721FR5720
Info Block Info length 01A00h 05h 05h 05h 05h 05h
CRC length 01A01h 05h 05h 05h 05h 05h
CRC value 01A02h per unit per unit per unit per unit per unit
01A03h per unit per unit per unit per unit per unit
Device ID 01A04h 73h 72h 71h 77h 70h
Device ID 01A05h 81h 81h 81h 80h 81h
Hardware revision 01A06h per unit per unit per unit per unit per unit
Firmware revision 01A07h per unit per unit per unit per unit per unit
Die Record Die record tag 01A08h 08h 08h 08h 08h 08h
Die record length 01A09h 0Ah 0Ah 0Ah 0Ah 0Ah
Lot/wafer ID 01A0Ah per unit per unit per unit per unit per unit
01A0Bh per unit per unit per unit per unit per unit
01A0Ch per unit per unit per unit per unit per unit
01A0Dh per unit per unit per unit per unit per unit
Die X position 01A0Eh per unit per unit per unit per unit per unit
01A0Fh per unit per unit per unit per unit per unit
Die Y position 01A10h per unit per unit per unit per unit per unit
01A11h per unit per unit per unit per unit per unit
Test results 01A12h per unit per unit per unit per unit per unit
01A13h per unit per unit per unit per unit per unit
ADC10 Calibration ADC10 calibration tag 01A14h 13h 13h 13h 05h 13h
ADC10 calibration length 01A15h 10h 10h 10h 10h 10h
ADC gain factor 01A16h per unit NA NA per unit per unit
01A17h per unit NA NA per unit per unit
ADC offset 01A18h per unit NA NA per unit per unit
01A19h per unit NA NA per unit per unit
ADC 1.5-V reference
Temp. sensor 30°C
01A1Ah per unit NA NA per unit per unit
01A1Bh per unit NA NA per unit per unit
ADC 1.5-V reference
Temp. sensor 85°C
01A1Ch per unit NA NA per unit per unit
01A1Dh per unit NA NA per unit per unit
ADC 2.0-V reference
Temp. sensor 30°C
01A1Eh per unit NA NA per unit per unit
01A1Fh per unit NA NA per unit per unit
ADC 2.0-V reference
Temp. sensor 85°C
01A20h per unit NA NA per unit per unit
01A21h per unit NA NA per unit per unit
ADC 2.5-V reference
Temp. sensor 30°C
01A22h per unit NA NA per unit per unit
01A23h per unit NA NA per unit per unit
ADC 2.5-V reference
Temp. sensor 85°C
01A24h per unit NA NA per unit per unit
01A25h per unit NA NA per unit per unit
REF Calibration REF calibration tag 01A26h 12h 12h 12h 12h 12h
REF calibration length 01A27h 06h 06h 06h 06h 06h
REF 1.5-V reference 01A28h per unit per unit per unit per unit per unit
01A29h per unit per unit per unit per unit per unit
REF 2.0-V reference 01A2Ah per unit per unit per unit per unit per unit
01A2Bh per unit per unit per unit per unit per unit
REF 2.5-V reference 01A2Ch per unit per unit per unit per unit per unit
01A2Dh per unit per unit per unit per unit per unit
NA = Not applicable