ZHCSKM1D October 1997 – December 2019 OPA548
PRODUCTION DATA.
From Safe-Operating-Area we know we will must support 22.5 W of dissipation up to the 40°C ambient requirements of the application. This indicates the need for a heatsink with a RθHA < 2.5°C/W, such as an Aavid Thermalloy 530002B02500G.