SNAS856 September 2024 REF80
ADVANCE INFORMATION
The REF80 has integrated on chip heater, which is factory programmed to TSET = 105°C temperature. Heater regulates the TSET temperature to ± 1°C for entire operating temperature range. This results in 0.05ppm/°C tempco for REF80.
The temperature coefficient is calculated using the box method in which a box is formed by the min/max variation for the nominal output voltage over the operating temperature range. REF80 has a maximum temperature coefficient of 0.2ppm/°C for 0°C to70°C temperature range. The box method specifies limits for the temperature error but does not specify the exact shape and slope of the device under test. See SLYT183 for more information on the box method. The box method equation is shown in Equation 2: