over operating free-air temperature range unless otherwise noted(1)
(2)
|
MIN |
MAX |
UNIT |
Supply voltage, VCC |
–0.3 |
6 |
V |
Voltage at A or B |
–9 |
14 |
V |
Input voltage at D, DE, R or
RE |
–0.5 |
VCC + 0.5 |
V |
Voltage input, transient pulse, A and B,
through 100 Ω |
–25 |
25 |
V |
Receiver output current,
IO |
–11 |
11 |
mA |
Maximum Junction Temperature,
TJ |
|
150 |
°C |
Storage Temperature,
TSTG |
–65 |
150 |
°C |
(1) Stresses beyond those listed under Absolute Maximum
Ratings may cause permanent damage to the device. These are stress
ratings only, which do not imply functional operation of the device at these or
any other conditions beyond those indicated under Recommended Operating
Conditions. Exposure to absolute-maximum-rated conditions for extended
periods may affect device reliability.
(2) All voltage values, except differential I/O bus voltages,
are with respect to network ground terminal.