over operating free-air temperature range (unless otherwise noted) (1) (2) | MIN | MAX | UNIT |
---|
VCC | Supply voltage | –0.5 | 7 | V |
| Voltage range at A or B | –9 | 14 | V |
| Voltage range at any logic pin | –0.3 | VCC + 0.3 | V |
| Receiver output current | –24 | 24 | mA |
| Voltage input range, transient pulse, A and B, through 100 Ω (see Figure 8-13) | –50 | 50 | V |
TJ | Junction temperature | 170 | 170 | °C |
| Continuous total power dissipation | Refer to Section 7.11 | |
Tstg | Storage temperature | –65 | 130 | °C |
(1) Stresses beyond those listed under
Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under
Section 7.3 is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential I/O bus voltages, are with respect to network ground terminal.