ZHCS603D November   2011  – April 2022 SN65HVDA100-Q1

PRODUCTION DATA  

  1. 特性
  2. 应用
  3. 说明
  4. 说明(续)
  5. Revision History
  6. Pin Configuration and Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings (1) (1)
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Switching Characteristics
    7. 7.7 Dissipation Ratings
    8. 7.8 Typical Characteristics
  8. Parameter Measurement Information
    1. 8.1 17
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1  LIN (Local Interconnect Network) Bus
        1. 9.3.1.1 LIN Transmitter Characteristics
        2. 9.3.1.2 LIN Receiver Characteristics
          1. 9.3.1.2.1 Termination
      2. 9.3.2  TXD (Transmit Input / Output)
      3. 9.3.3  RXD (Receive Output)
      4. 9.3.4  VSUP (Supply Voltage)
      5. 9.3.5  GND (Ground)
      6. 9.3.6  EN (Enable Input)
      7. 9.3.7  NWake (High Voltage Wake Up Input)
      8. 9.3.8  INH (Inhibit Output)
      9. 9.3.9  TXD Dominant State Timeout
      10. 9.3.10 Thermal Shutdown
      11. 9.3.11 Bus Stuck Dominant System Fault: False Wake-Up Lockout
      12. 9.3.12 Undervoltage on VSUP
      13. 9.3.13 Unpowered Device Does Not Affect the LIN Bus
    4. 9.4 Device Functional Modes
      1. 9.4.1 Operating States
      2. 9.4.2 Normal Mode
      3. 9.4.3 Sleep Mode
      4. 9.4.4 Wake-Up Events
        1. 9.4.4.1 Wake-Up Request (RXD)
        2. 9.4.4.2 Wake-Up Source Recognition (TXD)
      5. 9.4.5 Standby Mode
      6. 9.4.6 Mode Transitions
  10. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
      3. 10.2.3 Application Curves
  11. 11Power Supply Recommendations
  12. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
  13. 13Device and Documentation Support
    1. 13.1 Documentation Support
      1. 13.1.1 Related Documentation
    2. 13.2 接收文档更新通知
    3. 13.3 支持资源
    4. 13.4 Trademarks
    5. 13.5 Electrostatic Discharge Caution
    6. 13.6 术语表
  14. 14Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Standby Mode

This mode is entered whenever a wake-up event occurs through LIN bus or NWake while the device is in sleep mode. The LIN bus responder termination circuit and INH are turned on when standby mode is entered. The application system powers up once INH is turned on, assuming the system is using a voltage regulator connected through INH. Standby mode is signaled through a low level on RXD.

When EN is set high while the device is in standby mode the device returns to normal mode and the normal transmission paths from TXD to LIN bus and LIN bus to RXD are enabled.

During power up if EN is low the device goes into Standby mode and if EN is high the device goes into Normal mode. EN has an internal pull-down resistor, so if the pin is floating in the system, the internal pull-down makes sure it is pulled low.

Note:

If the INH output of the SN65HVDA100-Q1 is not used to control the system power management (voltage regulators) and monitor wake-up sources, but sleep mode is used to reduce system current, the RXD pin is monitored to make sure SN65HVDA100-Q1 remains in sleep mode. If the SN65HVDA100-Q1 detects an undervoltage on VSUP, the RXD pin transitions low and signals to the software that the SN65HVDA100-Q1 is in standby mode and should be returned to sleep mode to return to the lowest power state.