ZHCSS09A february   2002  – april 2023 SN74AHC244Q

PRODMIX  

  1. 特性
  2. 应用
  3. 说明
  4. Revision History
  5. Function Table
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Switching Characteristics, VCC = 3.3 V ± 0.3 V
    7. 6.7 Switching Characteristics, VCC = 5 V ± 0.5 V
    8. 6.8 Noise Characteristics
    9. 6.9 Operating Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Device Functional Modes
  9. Application and Implementation
    1. 9.1 Power Supply Recommendations
    2. 9.2 Layout
      1. 9.2.1 Layout Guidelines
        1. 9.2.1.1 Layout Example
  10. 10Device and Documentation Support
    1. 10.1 Documentation Support
      1. 10.1.1 Related Documentation
    2. 10.2 接收文档更新通知
    3. 10.3 支持资源
    4. 10.4 Trademarks
    5. 10.5 静电放电警告
    6. 10.6 术语表
  11. 11Mechanical, Packaging, and Orderable Information

封装选项

请参考 PDF 数据表获取器件具体的封装图。

机械数据 (封装 | 引脚)
  • PW|20
  • DW|20
散热焊盘机械数据 (封装 | 引脚)
订购信息

Absolute Maximum Ratings

over operating free-air temperature range (unless otherwise noted)1
MIN MAX UNIT
VCC Supply voltage range –0.5 7 V
VI2 Input voltage range –0.5 7 V
VO2 Output voltage range –0.5 VCC + 0.5 V
IIK (VI < 0) Input clamp current –20 mA
IOK (VO < 0 or VO > VCC) Output clamp current ±20 mA
IO (VO = 0 to VCC) Continuous output current ±25 mA
VCC or GND Continuous current ±50 mA
Tstg Storage temperature range –65 150 °C
  1. Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
  2. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.