over operating free-air temperature range (unless otherwise noted)(1)(2)(3)(4)(5)(6)
|
MIN |
MAX |
UNIT |
Supply voltage range, VCC |
−0.5 |
7 |
V |
Control input voltage range, VIN (see
notes 1 and 2) |
−0.5 |
7 |
V |
Switch I/O
voltage range, VI/O (see notes 1, 2, and 3) |
−0.5 |
7 | V |
Control input clamp current, IIK
(VIN < 0) |
−50 |
|
mA |
I/O port clamp current,
II/OK(VI/O < 0) |
−50 |
|
mA |
ON-state switch current, II/O(see note
4) |
128 |
|
mA |
Continuous current through VCC or GND
terminals |
100 |
|
mA |
Package thermal impedance, θJA (see note
5): |
|
|
|
|
DBQ
package |
61 |
|
°C /W |
|
DW
package |
46 |
|
°C /W |
|
PW
package |
88 |
|
°C /W |
Tstg | Storage temperature |
−65 |
150 |
°C |
(1) Operation outside the Absolute
Maximum Ratings may cause permanent device damage. Absolute Maximum
Ratings do not imply functional operation of the device at these or any
other conditions beyond those listed under Recommended Operating
Conditions. If used outside the Recommended Operating Conditions
but within the Absolute Maximum Ratings, the device may not be fully
functional, and this may affect device reliability, functionality, performance,
and shorten the device lifetime.
(2) All voltage values are with respect to network ground
terminal GND.
(3) The input and output voltage ratings may be exceeded if the input and output
clamp-current ratings are observed.
(4) VI and VO are used to denote specific conditions for
VI/O.
(5) II and IO are used to denote specific conditions for
II/O.
(6) The package thermal impedance is calculated in accordance with JESD 51-7.