Over operating free-air temperature range (unless
otherwise noted)(1)
|
MIN |
MAX |
UNIT |
VCC |
Supply voltage |
–0.5 |
7 |
V |
VI |
Input voltage(2) |
–0.5 |
7 |
V |
VO |
Voltage range applied to any output in the high-impedance
or power-off state(2) |
–0.5 |
7 |
V |
VO |
Output voltage (2)(3) |
–0.5 |
VCC + 0.5 |
V |
IIK |
Input clamp current |
VI < 0 |
|
–20 |
mA |
IOK |
Output clamp current |
VO < 0 |
|
–50 |
mA |
IO |
Continuous output current |
VO = 0 to VCC |
|
±35 |
mA |
|
Continuous current through VCC or GND |
|
±70 |
mA |
θJA
|
Package thermal impedance |
|
83 |
°C/W |
Tstg |
Storage
temperature |
–65 |
150 |
°C |
(1) Stresses beyond those listed under “absolute maximum ratings”
may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those
indicated under "recommended operating conditions" is not implied. Exposure to
absolute-maximum-rated conditions for extended periods may affect device
reliability. The package thermal impedance is calculated in accordance with JESD
51-7.
(2) The input and output negative-voltage ratings may be exceeded if
the input and output current ratings are observed.
(3) This value is limited to 5.5 V maximum.