ZHCSKM5 December 2019 TAS2110
PRODUCTION DATA.
Latched interrupt readback.
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7 | INT_LTCH0[7] | R | 0h | Interrupt due to limiter mute.
0b = No interrupt 1b = Interrupt |
6 | INT_LTCH0[6] | R | 0h | Interrupt due to limiter infinite hold.
0b = No interrupt 1b = Interrupt |
5 | INT_LTCH0[5] | R | 0h | Interrupt due to limiter max attenuation.
0b = No interrupt 1b = Interrupt |
4 | INT_LTCH0[4] | R | 0h | Interrupt due to VBAT below limiter inflection point.
0b = No interrupt 1b = Interrupt |
3 | INT_LTCH0[3] | R | 0h | Interrupt due to limiter active
0b = No interrupt 1b = Interrupt |
2 | INT_LTCH0[2] | R | 0h | Interrupt due to TDM clock error
0b = No interrupt 1b = Interrupt |
1 | INT_LTCH0[1] | R | 0h | Interrupt due to over current error
0b = No interrupt 1b = Interrupt |
0 | INT_LTCH0[0] | R | 0h | Interrupt due to over temp error
0b = No interrupt 1b = Interrupt |