ZHCSF47E June 2016 – December 2017 TAS2560
PRODUCTION DATA.
Sets the clock error timeouts for detecting missing clocks
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Reserved | Reserved | CLK_E1_TIME[2:0] | CLK_E2_TIME[2:0] | ||||
RW-0h | RW-0h | RW-7h | RW-7h |
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7 | Reserved | RW | 0h | Reserved |
6 | Reserved | RW | 0h | Reserved |
5-3 | CLK_E1_TIME[2:0] | RW | 0h | The chip will shutdown with a clock error 1 is the clock input to the error 1 detection block is not present for the specified time. B0_P0_R5[0] will be set to high and must be cleared before repowering the device. The clock missing time is
0 = 11ms 1 = 22ms 2 = 44ms 3 = 87ms 4 = 174ms 5 = 350ms 6 = 700ms 7 = 1.2s |
2-0 | CLK_E2_TIME[2:0] | RW | 7h | The chip will shutdown with a clock error 1 is the clock input to the error 1 detection block is not present for the specified time. B0_P0_R5[0] will be set to high and must be cleared before repowering the device. The clock missing time is
0 = 11ms 1 = 22ms 2 = 44ms 3 = 87ms 4 = 174ms 5 = 350ms 6 = 700ms 7 = 1.2s |