ZHCSF47E June 2016 – December 2017 TAS2560
PRODUCTION DATA.
Request a die temperature reading and register to read back the die temperature range.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Reserved | DTMP_INIT | DTMP_VALID | DTMP_VAL[3:0] | ||||
RW-0h | RW-0h | R-0h | R-0h |
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7-6 | Reserved | RW | 0h | Reserved |
5 | DTMP_INIT | RW | 0h | Request a reading of the die temperature be performed. The die temp measurement acquisition is
0 = idle 1 = Initiated (self cleared when completed) |
4 | DTMP_VALID | R | 0h | Indicated the validity of the die temperature registers. This will be invalid when the acquisition is in progress. Die temperature reading is
0 = invalid 1 = valid |
3-0 | DTMP_VAL[3:0] | R | 0h | The last die temperature measurement was
0 = less than 30 C 1 = in the range 30 C to 50 C 2 = in the range 50 C to 65 C 3 = in the range 65 C to 80 C 4 = in the range 80 C to 85 C 5 = in the range 85 C to 90 C 6 = in the range 90 C to 95 C 7 = in the range 95 C to 100 C 8 = in the range 100 C to 105 C 9 = in the range 105 C to 110 C 10 = in the range 110 C to 115 C 11 = in the range 115 C to 120 C 12 = in the range 120 C to 125 C 13 = in the range 125 C to 130 C 14 = in the range 130 C to 140 C 15 = is greater than 140 C |