ZHCSF47E June 2016 – December 2017 TAS2560
PRODUCTION DATA.
Sets if the device will try to auto
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
Reserved | CLK_ERR2_AR | CLK_ERR1_AR | Reserved | ||||
RW-0h | RW-0h | RW-0h | RW-0h |
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7-4 | Reserved | RW | 0h | Reserved |
3 | CLK_ERR2_AR | RW | 0h | When an error occurs on clock error 2 block the device will
0 = perform a recovery when condition clears 1 = will shutdown and require user recovery |
2 | CLK_ERR1_AR | RW | 0h | When an error occurs on clock error 1 block the device will
0 = perform a recovery when condition clears 1 = will shutdown and require user recovery |
1-0 | Reserved | RW | 0h | Reserved |