SLASEI6A October 2019 – December 2019 TAS2564
PRODUCTION DATA.
ICLA time slot enables.
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7 | ICLA_GAIN_SEN[3] | RW | 0h | Time slot equals ICLA_GAIN_SLOT[5:0]+3. When enabled, the limiter will include this time slot in the alignment group.
0b = Disabled 1b = Enabled |
6 | ICLA_GAIN_SEN[2] | RW | 0h | Time slot equals ICLA_GAIN_SLOT[5:0]+2. When enabled, the limiter will include this time slot in the alignment group.
0b = Disabled 1b = Enabled |
5 | ICLA_GAIN_SEN[1] | RW | 0h | Time slot equals ICLA_GAIN_SLOT[5:0]+1. When enabled, the limiter will include this time slot in the alignment group.
0b = Disabled 1b = Enabled |
4 | ICLA_GAIN_SEN[0] | RW | 0h | Time slot equals ICLA_GAIN_SLOT[5:0]+0. When enabled, the limiter will include this time slot in the alignment group.
0b = Disabled 1b = Enabled |
3 | Reserved | RW | 0h | Reserved |
2 | Reserved | RW | 0h | Reserved |
1 | Reserved | RW | 0h | Reserved |
0 | Reserved | RW | 0h | Reserved |