ZHCSMU9A December 2020 – September 2021 TAS2764
PRODUCTION DATA
The following I2C sequence is an example of changing the sampling rate from 48 kHz to 44.1 kHz .
w 70 07 28 #Set DVC Ramp Rate to 0.5 dB / 8 samples
w 70 02 01 #Mute
d 1
w 70 02 02 #Software shutdown
w 70 08 39 #44.1KHz, Auto TDM off, Frame start High to Low
### change source sample rate now
w 70 02 01 #Take device out of low-power shutdown
d 1
w 70 02 00 #Un-mute