ZHCSJM6A April 2019 – October 2019 TAS6421-Q1
PRODUCTION DATA.
The AC Load Diagnostic Control 1 register is shown in Figure 52 and described in Table 25.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
CH1 GAIN | RESERVED | CH1 ENABLE | RESERVED | ||||
R/W-0 | R/W-0 |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7 | CH1: GAIN | R/W | 0 |
0: Gain 1 1: Gain 4 |
6–4 | RESERVED | R/W | 000 | RESERVED |
3 | CH1 ENABLE | R/W | 0 |
0: AC diagnostics disabled 1: Enable AC diagnostics |
2–0 | RESERVED | R/W | 000 | RESERVED |