ZHCSPC7B December   2022  – November 2023 TCA39416

PRODUCTION DATA  

  1.   1
  2. 特性
  3. 应用
  4. 说明
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Timing Requirements
    7. 5.7 Switching Characteristics
    8. 5.8 Typical Characteristics
  7. Parameter Measurement Information
    1. 6.1 Voltage Waveforms
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Architecture
      2. 7.3.2 Enable and Disable
      3. 7.3.3 Pull up resistors on I/O Lines
      4. 7.3.4 Input Driver Requirements
    4. 7.4 Device Functional Modes
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curve
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. Device and Documentation Support
    1. 9.1 Documentation Support
    2. 9.2 接收文档更新通知
    3. 9.3 支持资源
    4. 9.4 Trademarks
    5. 9.5 静电放电警告
    6. 9.6 术语表
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

封装选项

机械数据 (封装 | 引脚)
散热焊盘机械数据 (封装 | 引脚)
订购信息

Device Functional Modes

The TCA39416 device has two functional modes, enabled and disabled. To disable the device, set the OE input low, which disables the rise time and fall time accelerators, and prevents signals from propagating across the channels. The internal pull up resistors are also affected by the OE input and are disabled when OE input is low. Setting the OE input high enables the device. The internal pull-up resistors act has High-Keeper and are enabled based on respective VCC voltage when bus is high. Table 7-1 provides functional description for TCA39416.

Table 7-1 Functional table
Supply voltage(4) Input(1) I/O
VCCA VCCB OE(2)
0.72 V to 1.98 V 0.72 V to 1.98 V L disconnected
0.72 V to 1.98 V 0.72 V to 1.98 V H A1 = B1; A2 = B2
GND(3) GND(3) X disconnected
H = HIGH voltage level; L = LOW voltage level; X = don’t care
OE is referenced to VCCA. Pull OE low to place all outputs in 3-state mode.
When either VCCA or VCCB is at GND level, the device goes into power-down mode.