ZHCSCU3C January 2014 – September 2019 TCA5013
PRODUCTION DATA.
PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | ||
---|---|---|---|---|---|---|---|
VOL - CLK | Output Low voltage | IOL = -100 µA | 0.1 VCC | V | |||
VOH - CLK | Output high voltage | IOH = 100 µA | 0.9 VCC | V | |||
tR - CLK/ tF - CLK | Rise/Fall time | CL = 30 pF ;
10% to 90%; |
CLK slew rate settings register = 0000b | 7 | ns | ||
CLK slew rate settings register = 0001b | 9 | ||||||
CLK slew rate settings register = 0010b | 11 | ||||||
CLK slew rate settings register = 0011b | 13 | ||||||
CLK slew rate settings register = 0100b | 13.5 | ||||||
CLK slew rate settings register = 0101b | 14 | ||||||
CLK slew rate settings register = 0110b | 15 | ||||||
CLK slew rate settings register = 0111b | 16 | ||||||
CLK slew rate settings register = 1000b | 17 | ||||||
CLK slew rate settings register = 1001b | 18 | ||||||
CLK slew rate settings register = 1010b | 19 | ||||||
CLK slew rate settings register = 1011b | 20 | ||||||
CLK slew rate settings register = 1100b | 21 | ||||||
CLK slew rate settings register = 1101b | 22 | ||||||
CLK slew rate settings register = 1110b | 23 | ||||||
CLK slew rate settings register = 1111b | 25 | ||||||
CLKPU-PD-SKEW | Clock pull-up / pull-down skew | tR-CLK – tF-CLK / tF-CLK; CL = 30 pF | 10 | % | |||
fCLK | Frequency on CLK pin | CL = 30 pF | 20 | MHz | |||
D | Clock duty cycle | Internal clock = 1.2 MHz; CL = 30 pF | 45 | 55 | % |