ZHCSH32 November 2017 TLA2021 , TLA2022 , TLA2024
PRODUCTION DATA.
This section provides an example of an I2C communication sequence between a microcontroller (the master) and a TLA2024 (the slave) configured with a slave address of 1001 000 to start a single-shot conversion and subsequently read the conversion result.
Alternatively, poll the OS bit for a 1 as shown in Figure 22 to determine when the conversion result is ready for retrieval. This option does not work in continuous-conversion mode because the OS bit always reads 0.
To save time, a new conversion can also be started (step 4) before reading the conversion result (step 3). Figure 24 lists a legend for Figure 21 to Figure 23.